Dold RN 5883 Series Current Transformer, 3A Input, 3:1
- RS-stocknr.:
- 181-2771
- Fabrikantnummer:
- ND5015/035/61
- Fabrikant:
- Dold
Subtotaal (1 eenheid)*
€ 227,98
(excl. BTW)
€ 275,86
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 227,98 |
*prijsindicatie
- RS-stocknr.:
- 181-2771
- Fabrikantnummer:
- ND5015/035/61
- Fabrikant:
- Dold
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Dold | |
| Current Ratio | 3:1 | |
| Series | RN 5883 | |
| Input Current | 3A | |
| Overall Height | 67mm | |
| Overall Width | 88mm | |
| Overall Depth | 10.5mm | |
| Minimum Temperature | -40°C | |
| Maximum Temperature | +60°C | |
| Mounting Type | DIN Rail | |
| Dimensions | 88 x 46 x 67 mm | |
| Alles selecteren | ||
|---|---|---|
Merk Dold | ||
Current Ratio 3:1 | ||
Series RN 5883 | ||
Input Current 3A | ||
Overall Height 67mm | ||
Overall Width 88mm | ||
Overall Depth 10.5mm | ||
Minimum Temperature -40°C | ||
Maximum Temperature +60°C | ||
Mounting Type DIN Rail | ||
Dimensions 88 x 46 x 67 mm | ||
- Land van herkomst:
- DE
For AC and DC systems Type B
To detect earth faults in grounded voltage systems
4 setting ranges from 10 mA to 3 A
Manual reset, with alarm and pre-warning
With adjustable switching delay
Energized or de-energized on trip
LED indicator for operation, pre-alarm and alarm
With test function
LED-chain indicates fault current
As option with analogue output
Broken wire detection
Width: 52.5 mm
Application
The residual current monitor type B is designed to monitor DC systems and AC systems up to 250 Hz.
To detect earth faults in grounded voltage systems
4 setting ranges from 10 mA to 3 A
Manual reset, with alarm and pre-warning
With adjustable switching delay
Energized or de-energized on trip
LED indicator for operation, pre-alarm and alarm
With test function
LED-chain indicates fault current
As option with analogue output
Broken wire detection
Width: 52.5 mm
Application
The residual current monitor type B is designed to monitor DC systems and AC systems up to 250 Hz.
Gerelateerde Links
- Dold RN 5883 Series Current Transformer, 3A Input, 3:1
- LEM HX Series Current Transformer, 3A Input, 0.6mm Bore, ±15 V
- LEM HX Series Current Transformer, 3A Input, 0.6mm Bore, 12 → 15 V
- Siemens SIRIUS Series Straight Through Current Transformer, 3A Input, 3:1, 3 A Output
- Dold Residual Current Monitoring Relay, 2 Phase, DPDT, DIN Rail
- RS PRO Current Transformer, 1250:1, 61 x 51mm Bore
- RS PRO Current Transformer, 1500:1, 61 x 51mm Bore
- WAGO 855 Series DIN Rail Mounted Current Transformer, 35A Input, 1 A Output, 7.5mm Bore, 720 V