Gossen Metrawatt Current Clamp, 10 A DC Max, AC Adapter, 1000 A AC Max
- RS-stocknr.:
- 263-6772
- Fabrikantnummer:
- Z225A
- Fabrikant:
- Gossen Metrawatt
Subtotaal (1 eenheid)*
€ 831,23
(excl. BTW)
€ 1.005,79
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 05 oktober 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 831,23 |
*prijsindicatie
- RS-stocknr.:
- 263-6772
- Fabrikantnummer:
- Z225A
- Fabrikant:
- Gossen Metrawatt
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Gossen Metrawatt | |
| Adapter Type | AC | |
| Product Type | Current Clamp | |
| Maximum DC Current | 10A | |
| Maximum AC Current | 1000A | |
| Accuracy | 1 % | |
| Maximum Conductor Size | 52mm | |
| Cable Length | 1.5m | |
| Connector Type | Safety Angle Plug | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | EN 500822, IEC 10101, EN 500811 : Klasse B, IEC 10102032 | |
| Safety Category Level | CAT III, ARM Cortex | |
| Safety Category Voltage | 600V | |
| Alles selecteren | ||
|---|---|---|
Merk Gossen Metrawatt | ||
Adapter Type AC | ||
Product Type Current Clamp | ||
Maximum DC Current 10A | ||
Maximum AC Current 1000A | ||
Accuracy 1 % | ||
Maximum Conductor Size 52mm | ||
Cable Length 1.5m | ||
Connector Type Safety Angle Plug | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals EN 500822, IEC 10101, EN 500811 : Klasse B, IEC 10102032 | ||
Safety Category Level CAT III, ARM Cortex | ||
Safety Category Voltage 600V | ||
- Land van herkomst:
- FR
The Gossen Metrawatt current transformers serve to expand AC measuring ranges. In conjunction with indicating and recording instruments it is possible to measure AC currents on lines and bus bars without the need to interrupt them. The secondary connection is made via hard-wired leads with contact-protected connection plugs. A protective circuit prevents high voltages when the secondary circuit is interrupted.
Residual current measurements on three-wire cables
Heavy current measurements on conductors and rails with high accuracy
Gerelateerde Links
- Gossen Metrawatt Current Clamp, AC Adapter, 1000 A ac AC Max, AC Output
- Gossen Metrawatt Z219B Current Clamp, Clamp Meter Adapter Adapter, 100 A ac AC Max, Voltage Output
- Gossen Metrawatt Current Clamp, 10 A DC Max, AC Adapter, 150 A ac AC Max, Current Output
- Gossen Metrawatt Z502T Clamp Adapter
- Gossen Metrawatt Z501S Adapter
- Gossen Metrawatt Z501V Adapter
- Gossen Metrawatt Interface Adapter