Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 250V, 500V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 50A | |
| Power Rating | 22kW | |
| Series | 1SBL2 | |
| Function | Control Unit | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 4 NO/1 NC | |
| Auxiliary Contact Configuration | 1 NO/1 NC | |
| Number of Auxiliary Contacts | 2 | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Operational Current Ie | 50A | |
| Minimum Operating Temperature | -40°C | |
| Control Circuit Voltage Uc | 250V, 500V | |
| Maximum Operating Temperature | 70°C | |
| Width | 45mm | |
| Depth | 111.5mm | |
| Length | 111.5mm | |
| Standards/Approvals | CSA C22.2 n° 14, IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508 | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Contactor | ||
Coil Voltage 250V, 500V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 50A | ||
Power Rating 22kW | ||
Series 1SBL2 | ||
Function Control Unit | ||
Mount Type DIN Rail | ||
Normal State Configuration 4 NO/1 NC | ||
Auxiliary Contact Configuration 1 NO/1 NC | ||
Number of Auxiliary Contacts 2 | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Operational Current Ie 50A | ||
Minimum Operating Temperature -40°C | ||
Control Circuit Voltage Uc 250V, 500V | ||
Maximum Operating Temperature 70°C | ||
Width 45mm | ||
Depth 111.5mm | ||
Length 111.5mm | ||
Standards/Approvals CSA C22.2 n° 14, IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508 | ||
Pole and Throw Configuration 3P | ||
- Land van herkomst:
- FR
ABB 1SBL2 Series Contactor, 250-500V Coil Voltage, 50A Current Rating - 1SBL297001R1411
Features & Benefits
• Controls motors up to 22kW at 690V, optimising energy usage
• Auxiliary contact configuration supports additional control capabilities
• Rated operational current of 50A meets high power requirements
• DIN rail mounting facilitates straightforward installation and integration
Applications
• Suitable for automation systems requiring reliable switching
• Employed in power distribution to manage loads effectively
• Ideal for HVAC where motor control is essential
• Utilised in machinery that demands precise electrical control
How does the auxiliary contact configuration enhance functionality?
Can this contactor operate efficiently in extreme temperatures?
What type of terminals does this product use?
Gerelateerde Links
- ABB 1SBL2 Contactor, 250V, 500 V Coil, 4-Pole, 55 A, 11 kW 250V, 500 V, 2 NO/2 NC, 690V
- ABB 1SBL2 Contactor, 250V dc, 500 V dc Coil, 3-Pole, 50 A, 18.5 kW 250V dc, 500 V dc, 4 NO/1 NC, 690V
- ABB 1SBL2 Contactor, 250V, 500 V Coil, 3-Pole, 50 A, 22 kW 250V, 500 V, 3 NO, 690V
- ABB 1SBL2 Contactor, 250V, 500 V Coil, 4-Pole, 45 A, 11 kW, 4 NO, 690V
- ABB 1SBL2 Contactor, 250V, 500 V Coil, 3-Pole, 50 A, 15 kW 500V, 3 NO, 690V
- ABB 1SBL3 Contactor, 250V, 500 V Coil, 4-Pole, 105 A, 22 kW 250V, 500 V, 2 NO/2 NC, 690V
- ABB 1SBL36 Contactor, 250V, 500 V Coil, 3-Pole, 100 A, 30 kW 250V, 500 V, 4 NO/1 NC, 690V
- ABB 1SBL13 Contactor, 250V, 500 V Coil, 3-Pole, 25 A, 4 kW 250V, 500 V, 3 NO/1 NC, 690V