ABB 1SBL24 Contactor, 48V ac Coil, 3-Pole, 26 A 48V ac, 3 NO, 690V
- RS-stocknr.:
- 253-1960
- Fabrikantnummer:
- 1SBL241022R8310
- Fabrikant:
- ABB
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 253-1960
- Fabrikantnummer:
- 1SBL241022R8310
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 48V ac | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 26A | |
| Series | 1SBL24 | |
| Function | Control Unit | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 3 NO | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 1 NO | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Operational Current Ie | 16A | |
| Control Circuit Voltage Uc | 48V ac | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 70°C | |
| Width | 54mm | |
| Standards/Approvals | EU Directive 2011/65/EU RoHS Status | |
| Depth | 90mm | |
| Length | 94mm | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Contactor | ||
Coil Voltage 48V ac | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 26A | ||
Series 1SBL24 | ||
Function Control Unit | ||
Mount Type DIN Rail | ||
Normal State Configuration 3 NO | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 1 NO | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Operational Current Ie 16A | ||
Control Circuit Voltage Uc 48V ac | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 70°C | ||
Width 54mm | ||
Standards/Approvals EU Directive 2011/65/EU RoHS Status | ||
Depth 90mm | ||
Length 94mm | ||
Pole and Throw Configuration 3P | ||
- Land van herkomst:
- BG
ABB UA26 Series Contactor, 16A Operational Current, 48V Control Circuit Voltage Uc - 1SBL241022R8310
This contactor is a three-pole switching device designed for control of capacitor banks and general control circuits in industrial electrical installations. It operates from an AC control Coil and is intended for DIN‑rail mounting in panels where a Compact footprint and robust switching of reactive loads are required. The unit includes an integrated auxiliary contact for control signalling and is specified for use across a wide ambient temperature range.
Features & Benefits
• 16A operational current for switching moderate load currents
• 48 VAC Coil compatible with 50/60 Hz control supplies
• 3NO main poles with 1NO auxiliary contact for simplified control wiring
• Rated to 690V for high‑voltage capacitor circuits
• Screw terminals provide secure conductor connections
• Wide operating temperature range from −40 to 70 °C for harsh sites
• 48 VAC Coil compatible with 50/60 Hz control supplies
• 3NO main poles with 1NO auxiliary contact for simplified control wiring
• Rated to 690V for high‑voltage capacitor circuits
• Screw terminals provide secure conductor connections
• Wide operating temperature range from −40 to 70 °C for harsh sites
Applications
• Suitable for capacitor bank switching in power factor correction installations
• Can be used for control circuits in automation cabinets
• Ideal for retrofit DIN‑rail panels requiring Compact contactors
• Used with capacitor units where high Peak inrush currents are limited
• Can be used for control circuits in automation cabinets
• Ideal for retrofit DIN‑rail panels requiring Compact contactors
• Used with capacitor units where high Peak inrush currents are limited
What inrush conditions can it handle when switching capacitors?
It accepts capacitor bank inrush peaks up to 100 times the nominal rms current when capacitors are discharged to ≤50V before reclosing.
How Durable is the mechanism under cyclic operation?
Mechanical endurance is specified at 10 million operations and electrical life reaches 100,000 switching cycles under the stated capacitor switching conditions.
What mounting and Terminal arrangements are provided?
It is designed for DIN‑rail installation and uses screw‑type terminals with cable clamps for secure connections.
Which protection ratings and voltages apply to the main and auxiliary circuits?
Both main and auxiliary circuits are rated to 690V with an insulation voltage of 1,000V and an impulse withstand of 8 kV.
Gerelateerde Links
- ABB UA26 Contactor, 24V ac Coil, 3-Pole, 26 A 24V ac, 3 NO, 690V
- ABB UA26 Contactor, 110V, 120 V Coil, 3-Pole, 6 A 110V, 3 NO, 690V
- ABB UA26 Contactor, 380V, 400 V Coil, 3-Pole, 10 A 400V, 415 V, 3 NO, 690V
- Schneider Electric TeSyS K Contactor, 48V ac Coil, 3-Pole, 12 A 48V ac, 3 NO, 690V ac
- Schneider Electric TeSyS K Contactor, 48V ac Coil, 3-Pole, 16 A 48V ac, 3 NO, 690V ac
- Schneider Electric TeSys Contactor, 48V ac Coil, 3-Pole, 38 A, 3 kW 48V, 3 NO, 690V ac
- Siemens 3RT2 Contactor, 48V ac Coil, 3-Pole, 9 A, 4 kW 48V ac, 3 NO, 690V ac
- Schneider Electric LC1D Contactor, 48V ac Coil, 3-Pole, 9 A, 5.5 kW 48V ac, 3 NO, 690V ac