Martindale CM69 Clamp Meter, Max Current 60A ac CAT II 1000V With RS Calibration
- RS-stocknr.:
- 122-5536
- Fabrikantnummer:
- RSCM69
- Fabrikant:
- Martindale
Subtotaal (1 eenheid)*
€ 369,57
(excl. BTW)
€ 447,18
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
- 6 stuk(s) klaar voor verzending
- Plus verzending 4 stuk(s) vanaf 09 januari 2026
- Plus verzending 8 stuk(s) vanaf 06 februari 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 369,57 |
*prijsindicatie
- RS-stocknr.:
- 122-5536
- Fabrikantnummer:
- RSCM69
- Fabrikant:
- Martindale
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Martindale | |
| Absolute Maximum AC Current Measurement | 60A ac | |
| Absolute Maximum AC Voltage Measurement | 600V ac | |
| Absolute Maximum DC Voltage Measurement | 600V dc | |
| Absolute Maximum Resistance Measurement | 600kΩ | |
| Model Number | CM69 | |
| Calibrated | RSCAL | |
| AC Current Measurement Resolution | 1µA | |
| Clamp Meter Type | Leakage Clamp Meter | |
| Best AC Current Accuracy | 1 % + 8 Digits | |
| Best AC Voltage Accuracy | 1 % + 3 Digits | |
| Jaw Capacity Busbars | 20mm | |
| Functions Measured | AC Current, AC Voltage, Continuity, DC Voltage, Resistance | |
| Best DC Voltage Accuracy | 1 % + 2 Digits | |
| True RMS | Yes | |
| Safety Category Voltage | 300 V, 600 V, 1000V | |
| Battery Type | 1.5 V, AAA, Alkaline | |
| Safety Category | CAT II 1000 V, CAT III 1000 V, CAT III 600 V, CAT IV 300 V, CAT IV 600V | |
| Best Resistance Measurement Accuracy | 1 % + 2 Digits | |
| Display Type | Backlit LCD | |
| Maximum Operating Temperature | +40°C | |
| Dimensions | 206 x 76 x 33.5mm | |
| DC Voltage Measurement Resolution | 10mV | |
| Minimum Operating Temperature | 0°C | |
| Height | 33.5mm | |
| AC Voltage Measurement Resolution | 10mV | |
| Maximum Conductor Size | 20mm | |
| Battery Life | 40 h @ AC, 60 h @ DC | |
| Weight | 262g | |
| Safety Category Level | CAT II, CAT III, CAT IV | |
| Power Source | Battery | |
| Width | 76mm | |
| Length | 206mm | |
| Resistance Measurement Resolution | 100mΩ | |
| Alles selecteren | ||
|---|---|---|
Merk Martindale | ||
Absolute Maximum AC Current Measurement 60A ac | ||
Absolute Maximum AC Voltage Measurement 600V ac | ||
Absolute Maximum DC Voltage Measurement 600V dc | ||
Absolute Maximum Resistance Measurement 600kΩ | ||
Model Number CM69 | ||
Calibrated RSCAL | ||
AC Current Measurement Resolution 1µA | ||
Clamp Meter Type Leakage Clamp Meter | ||
Best AC Current Accuracy 1 % + 8 Digits | ||
Best AC Voltage Accuracy 1 % + 3 Digits | ||
Jaw Capacity Busbars 20mm | ||
Functions Measured AC Current, AC Voltage, Continuity, DC Voltage, Resistance | ||
Best DC Voltage Accuracy 1 % + 2 Digits | ||
True RMS Yes | ||
Safety Category Voltage 300 V, 600 V, 1000V | ||
Battery Type 1.5 V, AAA, Alkaline | ||
Safety Category CAT II 1000 V, CAT III 1000 V, CAT III 600 V, CAT IV 300 V, CAT IV 600V | ||
Best Resistance Measurement Accuracy 1 % + 2 Digits | ||
Display Type Backlit LCD | ||
Maximum Operating Temperature +40°C | ||
Dimensions 206 x 76 x 33.5mm | ||
DC Voltage Measurement Resolution 10mV | ||
Minimum Operating Temperature 0°C | ||
Height 33.5mm | ||
AC Voltage Measurement Resolution 10mV | ||
Maximum Conductor Size 20mm | ||
Battery Life 40 h @ AC, 60 h @ DC | ||
Weight 262g | ||
Safety Category Level CAT II, CAT III, CAT IV | ||
Power Source Battery | ||
Width 76mm | ||
Length 206mm | ||
Resistance Measurement Resolution 100mΩ | ||
Vrijgesteld
- Land van herkomst:
- TW
Martindale CM69 TRMS AC Earth Leakage Clampmeter
Earth leakage clamps operate by clamping around both the live and neutral conductors. They also measure the difference between the currents flowing, allowing the "leakage value" to be displayed. Alternatively clamping around the earth conductor displays the earth leakage current.
Features and Benefits
Switchable low pass filter
TRMS measurement
Troubleshooting of RCD nuisance tripping
Periodic measurement of leakage current @ 50 Hz to check for insulation deterioration
Accurate measurement of triple neutral currents and other distorted waveforms
Differential current measurement for appliance testing
Auto ranging
High contrast backlit display
Supplied with
Gerelateerde Links
- Martindale CM69 Clamp Meter, Max Current 60A ac CAT II 1000V With UKAS Calibration
- Martindale CM69 Clamp Meter, Max Current 60A ac CAT II 1000V
- Martindale MARCM87 Clamp Meter, 2000A dc, Max Current 1500A ac CAT II 1000V With RS Calibration
- Martindale MARCM87 Clamp Meter, 2000A dc, Max Current 1500A ac CAT II 1000V With UKAS Calibration
- Martindale MARCM87 Clamp Meter, 2000A dc, Max Current 1500A ac CAT II 1000V
- RS PRO ICM33II Clamp Meter, Max Current 600A ac CAT II 1000 V, CAT III 600 V With UKAS Calibration
- RS PRO ICM33II Clamp Meter, Max Current 600A ac CAT II 1000 V, CAT III 600 V With RS Calibration
- ISO-TECH ICMA6 Clamp Meter, Max Current 600A ac CAT II 1000 V CAT III 600 V With UKAS Calibration