SolaHD 20kVA Chassis Mounting Transformer, 133V ac
- RS-stocknr.:
- 890-8693
- Fabrikantnummer:
- DT661H20S
- Fabrikant:
- SolaHD
Subtotaal (1 eenheid)*
€ 1.764,41
(excl. BTW)
€ 2.134,94
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 11 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.764,41 |
*prijsindicatie
- RS-stocknr.:
- 890-8693
- Fabrikantnummer:
- DT661H20S
- Fabrikant:
- SolaHD
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | SolaHD | |
| Primary Voltage Rating | 460V ac | |
| Secondary Voltage Rating | 133 V ac, 230V ac | |
| Power Rating | 20kVA | |
| Mounting Type | Panel Mount | |
| Width | 18in | |
| Depth | 14in | |
| Dimensions | 23 x 18 x 14in | |
| Weight | 210lb | |
| Maximum Operating Frequency | 60Hz | |
| Alles selecteren | ||
|---|---|---|
Merk SolaHD | ||
Primary Voltage Rating 460V ac | ||
Secondary Voltage Rating 133 V ac, 230V ac | ||
Power Rating 20kVA | ||
Mounting Type Panel Mount | ||
Width 18in | ||
Depth 14in | ||
Dimensions 23 x 18 x 14in | ||
Weight 210lb | ||
Maximum Operating Frequency 60Hz | ||
- Land van herkomst:
- US
SolaHD Drive Isolation Transformers - DT Series
Drive isolation transformers from SolaHD. DT series of transformer is designed to handle the mechanical stress, voltage demands and harmonics associated with SCR (Silicon Control Rectifier) variable speed motor drive applications. The transformer must offer a voltage change to match the required voltage of the SCR Drive. Available in a 3 phase unit from 7.5 kVA to 440 kVA.
Available from 7.5 kVA → 440 kVA, 3 Phase, 60 Hz
Isolation minimises load disturbances caused by the SCR drive
Taps on all units for adjustment to incoming source voltage
Shielding attenuates line to ground noise
UL 3R enclosures when used with optional weather shield
UL Listed
Isolation minimises load disturbances caused by the SCR drive
Taps on all units for adjustment to incoming source voltage
Shielding attenuates line to ground noise
UL 3R enclosures when used with optional weather shield
UL Listed
Gerelateerde Links
- SolaHD 3kVA Chassis Mounting Transformer, 120V ac
- SolaHD 0.75kVA Chassis Mounting Transformer, 120V ac
- SolaHD 2kVA Chassis Mounting Transformer, 120V ac
- SolaHD 1kVA Chassis Mounting Transformer, 24V ac
- SolaHD 1kVA Chassis Mounting Transformer, 120V ac
- SolaHD 1.5kVA Chassis Mounting Transformer, 120V ac
- SolaHD 1kVA Chassis Mounting Transformer, 12V ac
- SolaHD 5kVA Chassis Mounting Transformer, 120V ac