Hanna Instruments HI-7061L Buffer Solution, 500ml Bottle
- RS-stocknr.:
- 375-1868
- Artikelnummer Distrelec:
- 304-11-301
- Fabrikantnummer:
- HI-7061L
- Fabrikant:
- Hanna Instruments
Subtotaal (1 eenheid)*
€ 25,98
(excl. BTW)
€ 31,44
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- 9 stuk(s) klaar voor verzending
- 26 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 25,98 |
*prijsindicatie
- RS-stocknr.:
- 375-1868
- Artikelnummer Distrelec:
- 304-11-301
- Fabrikantnummer:
- HI-7061L
- Fabrikant:
- Hanna Instruments
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Hanna Instruments | |
| Solution Type | Cleaning | |
| Pack Quantity | 500ml | |
| Pack Type | Bottle | |
| Alles selecteren | ||
|---|---|---|
Merk Hanna Instruments | ||
Solution Type Cleaning | ||
Pack Quantity 500ml | ||
Pack Type Bottle | ||
Vrijgesteld
Hanna Instruments pH & Water Analysis Electrode Cleaning and Storage Solutions
Accessories for Electrodes, Hanna Instruments offer solutions ideal for maintenance, calibration and storage. Made with chemicals that are traceable and conform to international standards. Preventing premature failure and reliable and accurate pH measurement their cleaning and storage solutions are of high quality.
Cleaning Solution:
Used for cleaning the liquid junction of electrodes, regular maintenance with this cleaning solution prevents clogging which often leads to inaccurate readings. Containing Hydrochloric Acid 0.034%, protective equipment should be used as per the manufacturers guidelines. Supplied in a 460ml bottle.
Storage Solution:
Used to store the glass probes and re-calibrate meters, the storage solution is a buffer with antibacterial properties. This solution is prepared with high grade Potassium Chloride and Potassium hydrogen Phthalate by titration with NIST 2201 standardised Silver Nitrate and NIST 84j standardised Sodium Hydroxide Solution respectively. Supplied in a 460ml bottle.
Note: Never store Electrodes in distilled or deionized water.
Frequently asked questions:
How often should you clean Electrodes?
Hard waters, viscous and dirty samples are two of the many reasons Electrodes need regular cleaning. Cleaning should be a regular preventative maintenance procedure to prevent premature electrode failure, ideally once a day or at least once per week. Maintenance should be carried out regularly or as soon as build up has been detected.
How to know if an Electrode needs cleaning:
Noise - If readings fluctuate the junction could be clogged or dirty and may need cleaning.
Dry Membrane/Junction or Low Slope - The Electrode will need soaking in a storage solution.
No Slope - If the pH meter reads the same value constantly there could be cracks and an electrode replacement would be needed as apposed to cleaning.
Slow Response/Excessive drift - The tip will need soaking in a cleaning solution, and then a storage solution to re-calibrate the meter.
Always follow manufacturers instructions for Electrode cleaning and storage.
Hard waters, viscous and dirty samples are two of the many reasons Electrodes need regular cleaning. Cleaning should be a regular preventative maintenance procedure to prevent premature electrode failure, ideally once a day or at least once per week. Maintenance should be carried out regularly or as soon as build up has been detected.
How to know if an Electrode needs cleaning:
Noise - If readings fluctuate the junction could be clogged or dirty and may need cleaning.
Dry Membrane/Junction or Low Slope - The Electrode will need soaking in a storage solution.
No Slope - If the pH meter reads the same value constantly there could be cracks and an electrode replacement would be needed as apposed to cleaning.
Slow Response/Excessive drift - The tip will need soaking in a cleaning solution, and then a storage solution to re-calibrate the meter.
Always follow manufacturers instructions for Electrode cleaning and storage.
Gerelateerde Links
- Hanna Instruments HI-7033L Buffer Solution 84μS/cm, 500ml Bottle
- Hanna Instruments HI7032L Buffer Solution, 500ml Bottle
- Hanna Instruments HI7020L Buffer Solution, 500ml Bottle
- Hanna Instruments HI-9828-25 Buffer Solution 5mS/cm, 500ml Bottle, 6.86pH
- Hanna Instruments HI7009L pH Buffer Solution, 500ml Bottle, 9.18
- Hanna Instruments HI-7040L Buffer Solution, 460ml Bottle
- Hanna Instruments HI-7010/1L Buffer Solution, 1L Bottle, 10.01pH
- Hanna Instruments HI-7004/1L Buffer Solution, 1L Bottle, 4.01pH