TDK-Lambda 150W Power Brick AC/DC Adapter 12V dc Output, 11.67A Output

Bulkkorting beschikbaar

Subtotaal (1 eenheid)*

€ 114,64

(excl. BTW)

€ 138,71

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 3 stuk(s) vanaf 22 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 - 4€ 114,64
5 - 9€ 108,91
10 - 24€ 103,18
25 - 49€ 100,31
50 +€ 97,44

*prijsindicatie

RS-stocknr.:
125-3764
Fabrikantnummer:
DT-150PW-120-D
Fabrikant:
TDK-Lambda
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

TDK-Lambda

Adapter Type

Power Brick Adapter

Plug Type

C14

Output Voltage

12V dc

Input Voltage

90 → 264V ac

Output Current

11.67A

Maximum Temperature

+60°C

Input Connector

IEC 320-C14

Number of Outputs

1

Power Rating

150W

Cable Length

1050mm

Efficiency

89%

Standards Met

CSA 60950-1, EN 55022-B, EN 55024, EN 69501-1, FCC Class B, IEC 60950-1, UL

MTBF

140000h

Energy Efficiency Level

VI

Load Regulation

-5 → +5%

Length

170mm

Width

85mm

Series

DT150-D

Depth

44mm

Minimum Temperature

-20°C

Land van herkomst:
TW

TDK-Lambda Desktop Power Supply


The TDK-Lambda DT150-C series desktop power supply is the latest invention with an adapter and a voltage rating of 12VDC. This power supply provides 140W of continuous output power in a high-quality compact enclosure suitable for many general power applications. It has an input frequency range from 47Hz to 63Hz. While the input voltage rating ranging from 90VAC to 264VAC, its maximum input current is 2.5A. The device has a compact (85 x 170 x 44mm) lightweight enclosure that has ERP level V compliance, the average efficiency of 87% and a low off load standby power consumption of less than 0.5W. It has an IEC 320-C14 input connector and 1050mm cable with moulded Kykon 4-pin connector.
Note:
MTBF to MIL-HNBK (100% load, 25°C ambient).

Features and Benefits


Output current is 11.67A
Regulation is ± 5%
PFC typically 0.9 at full load (meets EN61000-3-2)
Operating temperature ranges between 0°C and 40°C at full load with no derating required
Overvoltage and short-circuit protection
Leakage current is greater than 300uA at 264VAC input
Hold up time16ms at 115VAC input
DOE level VI and EU tier 2 efficiency levels
Power factor correction

Applications


Instrumentation
Industrial device

Certifications


EN55022-B
FCC class B
Safety class I
CSA/UL60950-1
EN609501-1
IEC60950-1