PR Electronics 5100 Series Galvanic Barrier, Current, RTD, Thermocouple, Voltage Input, Current, Voltage Output, 19.2
- RS-stocknr.:
- 827-5495
- Fabrikantnummer:
- 5114B1B
- Fabrikant:
- PR Electronics
2 op voorraad - levertijd is 1 werkdag(en).
Toegevoegd
Prijs Per stuk
€ 784,30
(excl. BTW)
€ 949,00
(incl. BTW)
Aantal stuks | Per stuk |
1 + | € 784,30 |
- RS-stocknr.:
- 827-5495
- Fabrikantnummer:
- 5114B1B
- Fabrikant:
- PR Electronics
Wetgeving en conformiteit
- Land van herkomst:
- DK
Productomschrijving
PR Electronics 5114B Ex Programmable Transmitter
PR Electronics 5114B intrinsically safe programmable transmitter for linearizing electronic temperature measurement. With a wide variety of jumper selectable inputs for current/voltage or temperature and conversion of linear resistance the 5114 transmitters are suitable for a wide range of temperature measurement applications.
The 5114B transmitter can be configured, with or without a power supply, using the PReset software and the Loop Link communications unit (RS stock number 796-7020).
The 5114B signal conditioner is based on a microprocessor core with an efficient program operation. The basic calibration data and present set-up are stored in an EEPROM thereby avoiding the loss or change of data at power off.
The 5114B transmitter can be configured, with or without a power supply, using the PReset software and the Loop Link communications unit (RS stock number 796-7020).
The 5114B signal conditioner is based on a microprocessor core with an efficient program operation. The basic calibration data and present set-up are stored in an EEPROM thereby avoiding the loss or change of data at power off.
Features and Benefits
Input for RTD, TC, mV, linear resistance, mA and V
Automatic 4- / 3-wire or programmable 2-wire cable compensation
Active or passive current output and selectable voltage output
Programmable current (0...100 mA) and voltage (0...250 VDC) inputs.
Universal voltage supply
3.75 kVac galvanic isolation
Configurable sensor error detection including NAMUR NE43
Separation of circuits in PELV/SELV installations
I.S. barrier for temperature sensors, potentiometers, and current / voltage signals
I.S. barrier with I.S. power supply for 2-wire transmitters in zone 0, 1, 2, 20, 21 and 2
Automatic 4- / 3-wire or programmable 2-wire cable compensation
Active or passive current output and selectable voltage output
Programmable current (0...100 mA) and voltage (0...250 VDC) inputs.
Universal voltage supply
3.75 kVac galvanic isolation
Configurable sensor error detection including NAMUR NE43
Separation of circuits in PELV/SELV installations
I.S. barrier for temperature sensors, potentiometers, and current / voltage signals
I.S. barrier with I.S. power supply for 2-wire transmitters in zone 0, 1, 2, 20, 21 and 2
Note
Not suitable for new installations requiring certification to the latest ATEX standards - see ATEX certificate DEMKO 99ATEX127186 and EU Declaration of Conformity for details
PR Electronics - Ex Interfaces
Specificaties
Kenmerk | Waarde |
---|---|
Module Type | Programmable Transmitter |
Input Signal Type | Current, RTD, Thermocouple, Voltage |
Output Signal Type | Current, Voltage |
Supply Voltage | 19.2 → 300 V dc, 21.6 → 253V ac |
Hazardous Area Certification | ATEX |
Operating Temperature Range | -20 → +60°C |
Series | 5100 |
Maximum Operating Temperature | +60°C |
Number of Channels | 2 |