2 Output Toroidal Transformer, 15VA, 2 x 9V ac

Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: IN
Productomschrijving

Miniature Encapsulated PCB Mount 115/230Vac Primary Transformers

This series of fully encapsulated PCB mounting toroidal transformers feature twin 115 V ac 50/60Hz primary windings that can be connected in series to a 230 V supply or in parallel for 115 V supplies. With a low weight and compact size, these toroidal transformers are ideal where space is at a premium, offering low magnetic interference, low noise and high efficiency. An M4 central bush allows for easy mounting

Low profile compact design
Fully encapsulated to UL94-V0
Extremely low level of radiated magnetic field
Extremely low level of hum and noise
High efficiency and low temperature rise
Ease of mounting
100% electrical and flash tested

Standards

EN60950, VDE0805, UL506, UL1950, UL6500

Approvals

UL recognised, VDE

//media.rs-online.com/t_line/L223898-01.gif

Approvals

EN60950; VDE 0805 (VDE 5803UG); UL 506 (E215495); UL 1950 (E218027; UL 6500 (E218027)

Encapsulated – Toroidal

Note

Fixing screws not provided

Specificaties
Kenmerk Waarde
Primary Voltage Rating 115V ac, 230V ac
Secondary Voltage Rating 2 x 9V ac
Power Rating 15VA
Number of Outputs 2
Secondary Current 833mA
Weight 304g
Dimensions 60 x 60 x 26.3mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Mounting Type PCB
Termination Type Pin
Fixing Hole Diameter M4
Maximum Temperature +60°C
279 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
17,73
(excl. BTW)
21,45
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
17,73 €
10 - 24
15,97 €
25 - 49
15,07 €
50 - 99
14,20 €
100 +
13,31 €
Related Products
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).