Dehn 255 V ac 100kA DV Lightning Arrester, DIN Rail Mounting

  • RS-stocknr. 768-1710
  • Fabrikantnummer DV M TNS 255
  • Fabrikant Dehn
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

DEHNventil Surge Arresters Type 1/2

Type 1 and 2 prewired spark gap based combined lightning current and surge arresters consisting of a base and plug in modules.

Maximum system availability and reliability due to the RADAX Flow follow current limitation
No tripping of 20amp gL/gG fuses up to short circuit currents of 50kA
Discharge capacity of 100kA with 10/350 microsecond lightning waveform
Capable of protecting terminal equipment
Operating state and fault indication with indicator flag and/or optional remote contact in base
Easy replacement of protection modules requires no tools due to lock in system.
Coordinated with other Dehn Redline products to meet BS7671 amendment 1

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage and current surges depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Specificaties
Kenmerk Waarde
Suppressor Type Lightning Arrester
Maximum Voltage Rating 255 V ac
Mounting Type DIN Rail
Maximum Surge Current 100kA
Series DV
Length 90mm
Depth 144mm
Height 66mm
Dimensions 90 x 144 x 66mm
Minimum Operating Temperature -40°C
Maximum Operating Temperature +60°C
2 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
754,82
(excl. BTW)
913,33
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
754,82 €
10 - 19
679,33 €
20 - 24
618,48 €
25 - 49
594,70 €
50 +
583,48 €
Related Products
Frequency error range detection 35-75 HzOperating voltage 90V ...
Description:
Frequency error range detection 35-75 HzOperating voltage 90V to 300VLow voltage protection (LVD) Range 50V to 300VHigh voltage protection (HVD) Range 50V to 300V TimeSave™ function (Intelligent time delay)AVS™ function (Automatic Voltage Switcher) Programmable startup delay (0-1000hr range).
STP T12 25 is the series of combined ...
Description:
STP T12 25 is the series of combined Type 1+2/Class I+II devices for discharging lightning currents and protecting against voltage surges. Suitable as the first step of protection in incoming power supply panels and areas with exposure to the atmosphere, ...
Valvetrab Surge protection for Photovoltaic equipment provides an ...
Description:
Valvetrab Surge protection for Photovoltaic equipment provides an effective method of limiting high-energy transients such as lightning strikes. These are a type 2 protective measure for green renewable energy PV systems which significantly increases their availability and operability. The Valvetrab ...
Data-line lightning current and surge arresters with a ...
Description:
Data-line lightning current and surge arresters with a variety of mounting options for the protection of Telephone lines, COAX, CCTV and Ethernet based networks. The application specific designs can be retro fitted without complication, being easy to insert into networks ...