Softstarter

  • RS-stocknr. 181-2800
  • Fabrikantnummer UH9018 3AC400V 50/60Hz 1,5kW
  • Fabrikant Dold
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

soft start with soft stop For motors from 1.5 kW to 7.5 kW 2-phase control Adjustable ramp time, starting torque and starting voltage Kickstart-(Boost-)function DIN-rail mounting Width: 45 mm Advantages / Customer benefit Protection of the drive unit Integrated bridging contactor (Bypass) Easy operation Comprehensive diagnostic via LED-flashing codes possible Application Motors with gear, belt or chain drive Fans, pumps, conveyor systems, compressors Woodworking machines, centrifuges Packaging machines, door drives Start current limiting on 3 phase motors

Specificaties
Kenmerk Waarde
Phase 3
Supply Voltage 400 V ac
Current Rating 16 A
Voltage Rating 400 V ac
Control Voltage 10 <arrow/> 42 V dc
Power Rating 1.5 kW
IP Rating IP20
Overall Length 45mm
Overall Width 121mm
Overall Depth 107mm
Minimum Operating Temperature 0°C
Maximum Operating Temperature +45°C
Series UH9018
Mounting Type DIN Rail
1 op voorraad - levertijd is 1 werkdag(en)
Prijs Each
279,35
(excl. BTW)
338,01
(incl. BTW)
Aantal stuks
Per stuk
1 +
279,35 €
Related Products
May be integrated into a motor control system ...
Description:
May be integrated into a motor control system using other Sirius control gear products, e.g. 3 pole circuit breakers from the 3RV10 range (see Control Gear section)Two phase control, plus soft starting and stopping of three phase asynchronous motorsLow power ...
Siemens SIRIUS 3RW52 soft starters are the ideal ...
Description:
Siemens SIRIUS 3RW52 soft starters are the ideal solution when star/delta starting is not suitable in standard applications. With ideal 3-phase motor control, they cover the performance range from 5.5 kW to 560 kW (at 400 V). • Simple and ...
Adjustable ramp rate of between 1 to 60 ...
Description:
Adjustable ramp rate of between 1 to 60 secondsAdjustable pedestal 10-50%Internal snubberHigh inrush capabilitySuitable for most resistive & inductive loads such as heat lamps, fans, pumps and other a.c. motor loads.
Soft starters were developed to overcome the drawbacks ...
Description:
Soft starters were developed to overcome the drawbacks of direct on line (DOL) and star-delta starting of single and three phase a.c. induction motors, such as high starting currents, voltage peaks and mechanical snatch.,Soft starters achieve these benefits by controlling ...