9V ac 2 Output Through Hole PCB Transformer, 6VA

  • RS-stocknr. 161-7823
  • Fabrikantnummer FL 6/9
  • Fabrikant Block
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

PCB Mounting Low Profile 115 / 230Vac Primary

Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection
Twin secondary windings for series or parallel connection
Low profile compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure board mounting
Standard: EN60742, VDE 0551, IEC 61558

Note

Transformer with 2 x 24V outputs are not VDE, SEV approved.

Standards

VD 61 558

//media.rs-online.com/t_line/L201683-01.gif
Specificaties
Kenmerk Waarde
Secondary Voltage Rating 9V ac
Power Rating 6VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 53mm
Width 22.6mm
Depth 44mm
Dimensions 53 x 22.6 x 44mm
Weight 175g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
140 op voorraad - levertijd is 1 werkdag(en).
Prijs Each (In a Tray of 35)
8,505
(excl. BTW)
10,291
(incl. BTW)
Aantal stuks
Per stuk
Per tray*
35 +
8,505 €
297,675 €
*prijsindicatie
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range ...
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings ...
Description:
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedHigh efficiency and ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...