The 100E wire is rail approved compliant with EN50306-2, EN50306-3, EN50306-4. 100E is suitable for all new rail builds within the EU.
Lightweight
Thin walled
30% lighter than similar thick walled wire
Dual jacket insulation
Rail market
Underground metro tunnels
Signal and power applications for rolling stock and tunnels
EN50306-2, EN50306-3, EN50306-4
Kenmerk | Waarde |
---|---|
Number of Cores | 2 |
Cross Sectional Area | 0.5 mm² |
Screened/Unscreened | Screened |
Length | 100m |
Sheath Colour | Black |
American Wire Gauge | 20 AWG |
Outer Diameter | 4.3mm |
Screen Type | Braid, Foil |
Maximum Operating Temperature | +105°C |
Sheath Material | Low Smoke Zero Halogen (LSZH) |
Voltage Rating | 300 V |
Fire Behaviour | Halogen Free |
Series | 100E |
Conductor Material | Copper |
Drain Wire | No |
Minimum Operating Temperature | -30°C |
Minimum Bend Radius | 10 x Diameter |
Insulation Material | LSZH |