ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 180 → 280V ac, DIN Rail
- RS-stocknr.:
- 775-7918
- Fabrikantnummer:
- 1SVR730885R3300 CM-MPS.21S
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 236,09
(excl. BTW)
€ 285,67
(incl. BTW)
GRATIS bezorging voor bestellingen vanaf € 75,00
Op voorraad
- Plus verzending 4 stuk(s) vanaf 08 december 2025
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 236,09 |
*prijsindicatie
- RS-stocknr.:
- 775-7918
- Fabrikantnummer:
- 1SVR730885R3300 CM-MPS.21S
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en conformiteit
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Monitoring Application | Phase, Voltage | |
| Electrical Phase | 3 | |
| Contact Configuration | DPDT | |
| Voltage Sensing Range | 180 → 280V ac | |
| Voltage Sensitivity | Overvoltage, Undervoltage | |
| Mounting Type | DIN Rail | |
| Phase Sensitivity | NEUTRAL, Phase Failure, Phase Imbalance, Phase Sequence | |
| Time Delay | 0.1 → 30 s, 0s | |
| Frequency Sensing Range | 45 → 65Hz | |
| Series | CM-MPS | |
| Width | 22.5mm | |
| Dimensions | 103.7 x 22.5 x 85.6mm | |
| Minimum Voltage Sensed | 180V ac | |
| Terminal Type | Screw | |
| Maximum Operating Temperature | +60°C | |
| Minimum Operating Temperature | -25°C | |
| Height | 85.6mm | |
| Operating Temperature Range | -25 → +60°C | |
| Standards Met | UL | |
| Length | 103.7mm | |
| Maximum Voltage Sensed | 280V ac | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Monitoring Application Phase, Voltage | ||
Electrical Phase 3 | ||
Contact Configuration DPDT | ||
Voltage Sensing Range 180 → 280V ac | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Mounting Type DIN Rail | ||
Phase Sensitivity NEUTRAL, Phase Failure, Phase Imbalance, Phase Sequence | ||
Time Delay 0.1 → 30 s, 0s | ||
Frequency Sensing Range 45 → 65Hz | ||
Series CM-MPS | ||
Width 22.5mm | ||
Dimensions 103.7 x 22.5 x 85.6mm | ||
Minimum Voltage Sensed 180V ac | ||
Terminal Type Screw | ||
Maximum Operating Temperature +60°C | ||
Minimum Operating Temperature -25°C | ||
Height 85.6mm | ||
Operating Temperature Range -25 → +60°C | ||
Standards Met UL | ||
Length 103.7mm | ||
Maximum Voltage Sensed 280V ac | ||
- Land van herkomst:
- DE
ABB CM-MPS Series Monitoring Relay, DPDT Contact Configuration, 180 to 280V AC Voltage Sensing Range - 1SVR730885R3300 CM-MPS.21S
This monitoring relay is a multifunctional device from the CM-MPS series, designed for effective monitoring in three-phase applications. With dimensions of 103.7 x 22.5 x 85.6mm, it operates within a voltage sensing range of 180-280 V AC and can handle electrical phases of up to three. The relay provides essential protection against voltage fluctuations and phase-related issues, ensuring system reliability.
Features & Benefits
• Monitors overvoltage and undervoltage conditions
• Detects phase imbalance and phase failure
• Adjustable tripping delay between 0 and 30 seconds
• Utilises DPDT contact configuration for versatile applications
• Suitable for mounting on standard DIN rails
• Wide operating temperature range from -25 to +60°C
• Detects phase imbalance and phase failure
• Adjustable tripping delay between 0 and 30 seconds
• Utilises DPDT contact configuration for versatile applications
• Suitable for mounting on standard DIN rails
• Wide operating temperature range from -25 to +60°C
Applications
• Used in industrial automation systems
• Suitable for three-phase electrical supply monitoring
• Employed in settings requiring phase sequence verification
• Ideal for needing neutral interruption detection
• Suitable for three-phase electrical supply monitoring
• Employed in settings requiring phase sequence verification
• Ideal for needing neutral interruption detection
How does the adjustable tripping delay enhance reliability in operations?
The adjustable tripping delay allows custom configuration between instantaneous and 30 seconds, enabling users to optimise the response time to faults without unnecessary interruptions. This ensures a fine balance between prompt action and avoiding nuisance tripping during transient conditions.
What are the key advantages of utilising a DPDT configuration?
The DPDT configuration offers flexibility by allowing two separate circuits to be managed simultaneously, providing enhanced control over monitoring and switching operations in various applications. This is particularly beneficial in complex systems where multiple conditions need to be monitored at once.
In which scenarios should the voltage sensitivity features be applied?
These voltage sensitivity features are crucial in environments prone to fluctuations, ensuring that equipment operates only within safe voltage limits. By monitoring both over and undervoltage events, it protects machinery from damage and enhances operational safety.
Gerelateerde Links
- Eaton Phase, Voltage Monitoring Relay, 180 → 280V ac, DIN Rail
- ABB Current Monitoring Relay, 1 Phase, DPDT, DIN Rail
- ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 90 → 170V ac, DIN Rail
- ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 300 → 500V ac, DIN Rail
- ABB Phase, Voltage Monitoring Relay with DPDT Contacts, 3 Phase, 90 → 170 V ac
- ABB Phase Monitoring Relay, 3 Phase, DPDT
- ABB Phase Monitoring Relay, 3 Phase, DPDT, DIN Rail
- ABB Voltage Monitoring Relay, 1 Phase, DPDT, DIN Rail
