Schneider Electric 400VA DIN Rail & Panel Mount Transformer, 230V ac, 400V ac Primary 1 x, 230V ac Secondary

Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: CZ
Productomschrijving

ABL 6TS safety transformers

Single-phase single-winding safety and isolation transformers.
Able to supply higher powers on occasion.
Feature a panel display to reduce ESD.
Screw termination.
Plate mounting.

Standards

  IEC 61558-2-6 , EN61558-2-6

Laminated Frame 230Vac Primary 75VA to 200VA (Multi Tapped)

Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding.

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Multi-hole frame fixing
Solder tag terminations
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac, 400V ac
Secondary Voltage Rating 230V ac
Power Rating 400VA
Mounting Type Chassis
Number of Outputs 1
Length 136mm
Width 140mm
Depth 120mm
Dimensions 136 x 140 x 120mm
Minimum Operating Frequency 47Hz
Maximum Operating Frequency 63Hz
Minimum Temperature -20°C
Maximum Temperature +50°C
Weight 6.5kg
5 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
119,66
(excl. BTW)
144,79
(incl. BTW)
Aantal stuks
Per stuk
1 +
119,66 €
Related Products
High quality safety and isolating transformers designed for ...
Description:
High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual secondaries are centre tapped. Earth terminal provided ...
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.
The International series transformers have been designed to ...
Description:
The International series transformers have been designed to comply with the demands of electromagnetic control components which can demand inrush currents of up to 10 times the nominal rating without sacrificing secondary voltage stability beyond practical limits. They fully comply ...
The International series transformers have been designed to ...
Description:
The International series transformers have been designed to comply with the demands of electromagnetic control components which can demand inrush currents of up to 10 times the nominal rating without sacrificing secondary voltage stability beyond practical limits. They fully comply ...