LEM HAS Series Open Loop Current Sensor, ±600A

  • RS-stocknr. 301-9502
  • Fabrikantnummer HAS 200S
  • Fabrikant LEM
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: CN
Productomschrijving

HAS-P Series

Single-pole Hall effect current transducers
Measurement of inserted conductor
Voltage output, Vout = ±4V
Capable of measuring complex signals
Excellent precision and good linearity
Low temperature drift
Body material Plastic; Polycarbonate PBT
Operating Temperature Range -10 to +80°C
Secondary connector: stock no. 543-7738

Specificaties
Kenmerk Waarde
Sensor Technology Open Loop
Nominal Current ±600A
Supply Voltage 15 V
Sensor Type Hall Effect
Mounting Type Panel Mount
Frequency Bandwidth DC to 50 kHz
Accuracy ±1 %
Bore Size 20.4 x 10.4mm
Minimum Operating Temperature -10°C
Series HAS
Maximum Operating Temperature +80°C
Depth 30mm
Height 30mm
Width 40mm
17 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
55 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
22,30
(excl. BTW)
26,98
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
22,30 €
5 - 9
21,62 €
10 +
20,92 €
Related Products
Open loop current transducer with Hall effect measuring ...
Description:
Open loop current transducer with Hall effect measuring principleFor measuring DC, AC and pulse currentsWith galvanic separation between primary and secondary circuitsUnipolar voltage supplyFixed offset voltage with corresponding amplificationHousing made from insulating, self-extinguishing material UL94-V0.
CSLW Series miniature, open-loop AC current sensors from ...
Description:
CSLW Series miniature, open-loop AC current sensors from Honeywell. These sensors have a ratiometric output and incorporate a miniature linear Hall-effect sensor which is encapsulated in a PCB-mountable plastic package. A complete sensor is comprised of a sensor IC, flux ...
Linear current sensors from Honeywell incorporating LOHET II ...
Description:
Linear current sensors from Honeywell incorporating LOHET II Hall effect transducers. These devices have increased temperature stability and 10 times less temperature drift than the LOHET I types and produce a ratiometric output voltage that varies from 19% to 81% ...
The Honeywell CNS series of closed loop Hall-effect ...
Description:
The Honeywell CNS series of closed loop Hall-effect current sensors utilise the null balance or zero magnetic flux feedback method to provide accurate and repeatable measurements. The devices produce an output current which can be converted to a voltage by ...