Cooper Bussmann, 200A, B2, British Standard Fuse, gG - gM, 415V ac

Datasheets
Wetgeving en conformiteit
N.v.t.
Productomschrijving

Cooper Bussman Bolted Tag Fuse - British Standard

Cooper Bussman's bolted tag fuse is essentially a fuse that is fitted with brackets, these brackets allow the fuse to be bolted onto a fuse holder. Predominantly, this type of fuse is used within installations as a "weak link". They are designed to break when a fault occurs, such as an overcurrent or short circuit - they are a safety and damage measure. Cooper Bussman's fuses are commonly found within a multitude of industrial applications, electrical equipment and wiring systems

Features & Benefits

• The low-temperature rise enables the fuse to be suitable for high-density mounting applications
• Fuse links, specifically designed for the protection of applications
• Conforms to industry standards
• Low voltage fuse
• Suitable for three-phase applications
• Suitable for type 2 co-ordinated applications as defined in IEC 947-4
• Low power loss, typically 20% lower than the requirements of BS88

//media.rs-online.com/t_line/L413793-01.gif
Specificaties
Kenmerk Waarde
Current Rating 200 A
Fuse Size B2
Voltage Rating 415 V ac
Fuse Standard BS 88, IEC 269
Fixing Centres 111mm
Application Category GG - gM
Tag Width 19mm
High Rupture Capacity Yes
Overall Length 136mm
Body Diameter 31mm
Body Height 47mm
38 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
43,72
(excl. BTW)
52,90
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
43,72 €
5 - 24
39,33 €
25 - 49
37,16 €
50 - 99
32,78 €
100 +
30,61 €
Related Products
Semiconductor fuse links have a precise pre-determined performance ...
Description:
Semiconductor fuse links have a precise pre-determined performance which ensures a low arc voltage and minimum let through current. Semiconductor fuses are suited to application in the field of traction, distribution of power, motor drives and in process industries. Melt ...
As the fuse allows for the starting surge ...
Description:
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A. Breaking capacity ...
Eaton’s Bussmann® series fuse links, size C1, are ...
Description:
Eaton’s Bussmann® series fuse links, size C1, are specifically designed for the protection of general industrial applications e.g. power distribution, cable protection, motor protection. Good peak let-through current limitation1:1:6 Selective coordination ratio between “minor” and “major” ...
Utility fuse-link, LV, 500 A, AC 415 V ...
Description:
Utility fuse-link, LV, 500 A, AC 415 V 88/J, 49 x 131 mm, gL/gG , 92mm fixing centres.