PR Electronics 5437 Temperature Transmitter Linear Resistance, Potentiometer, RTD, Thermocouple, Voltage Input, 7.5
- RS-stocknr.:
- 175-6342
- Fabrikantnummer:
- 5437D2S
- Fabrikant:
- PR Electronics
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 29/05/2024, met een levertijd van 2 à 3 werkdagen.
Toegevoegd
Prijs Per stuk
€ 566,50
(excl. BTW)
€ 685,46
(incl. BTW)
Aantal stuks | Per stuk |
1 + | € 566,50 |
- RS-stocknr.:
- 175-6342
- Fabrikantnummer:
- 5437D2S
- Fabrikant:
- PR Electronics
Wetgeving en conformiteit
- Land van herkomst:
- DK
Productomschrijving
5437 HART 7 Dual Input Temperature Transmitter
PR Electronics 5437 dual input temperature transmitter offers unrivalled performance in the most demanding of applications to convert a wide array of input types to a 4 – 20 mA output signal. The transmitter has 7 input terminals measuring one or two sensors, including two 4-wire RTDs, with individual sensor error detection. Configuring the transmitter with either HART 7 or HART 5 protocols provide flexibility and future proof communication.
Sensor Inputs
The PR 5437 provides unrivalled dual input versatility. Virtually any thermocouple or RTD plus linear resistance up to 100 kΩ, potentiometer, and bipolar mV signals. Input sensor redundancy function maintains process availability and safety by seamlessly switching to backup sensor in the event of primary sensor failure. An alert via HART can be used to allow scheduling of maintenance on the faulty sensor.
Installation Characteristics
Wiring - Innovative housing design means the 5437 temperature transmitter can be wired from either the inside or the outside of the terminals.
1/4 centre hole – A large diameter centre hole for easier installation over a wide range of probe mounting diameters.
Loop test pins - Accessible test pins allow measurement of loop current directly while maintaining loop integrity.
Status LED - On-board LED indicates faults according to NAMUR NE44 and NE107.
Jumper pins - Jumpers allow selection of write protection and transmitter burnout options.
1/4 centre hole – A large diameter centre hole for easier installation over a wide range of probe mounting diameters.
Loop test pins - Accessible test pins allow measurement of loop current directly while maintaining loop integrity.
Status LED - On-board LED indicates faults according to NAMUR NE44 and NE107.
Jumper pins - Jumpers allow selection of write protection and transmitter burnout options.
Features and Benefits
LED provides visual notification of sensor, transmitter, and loop status
HART 7 and HART 5 communication protocols
Sensor redundancy function switches to backup sensor in the event of sensor failure
Sensor drift detection maintains measuring point reliability
Flexible dual input capability, with choice of output modes
Superior accuracy ensures true, reliable measurements
Fast response time easily supports safety and cost-critical applications
Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions
High galvanic isolation (2.5 kVAC / 55 VAC) providing protection from ground loops, high voltage transients and common mode interference
Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter
HART 7 and HART 5 communication protocols
Sensor redundancy function switches to backup sensor in the event of sensor failure
Sensor drift detection maintains measuring point reliability
Flexible dual input capability, with choice of output modes
Superior accuracy ensures true, reliable measurements
Fast response time easily supports safety and cost-critical applications
Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions
High galvanic isolation (2.5 kVAC / 55 VAC) providing protection from ground loops, high voltage transients and common mode interference
Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter
5437D2S
The 5437D can be mounted in zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D.
Approvals
SIL Certification
Full third party functional safety assessment to SIL 2 / SIL 3. According to IEC 61508-2010 including firmware assessment to SIL 3. SIL enable/disable function to suit individual applications.
Full third party functional safety assessment to SIL 2 / SIL 3. According to IEC 61508-2010 including firmware assessment to SIL 3. SIL enable/disable function to suit individual applications.
Specificaties
Kenmerk | Waarde |
---|---|
Input Type | Linear Resistance, Potentiometer, RTD, Thermocouple, Voltage |
Supply Voltage | 7.5 → 30 V dc |
Diameter | 44 mm |
Minimum Temperature Input | -200°C |
Maximum Temperature Input | 850°C |
Minimum Operating Temperature | -40°C |
Maximum Operating Temperature | +80°C |
Series | 5437 |
Depth | 20.2mm |
Hazardous Area Certification | ATEX |