1 Output 3.2W SMPS Transformer, 85 → 265 V ac, 85 → 370 V dc, 12V dc

  • RS-stocknr. 792-4394
  • Fabrikantnummer 47134
  • Fabrikant Myrra
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: CN
Productomschrijving

Single Unregulated DC Output Electronic Transformers

MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology
They are an interesting alternative to the traditional supply in the most common applications of power lower than 5W
ENERGY SAVING due to high efficiency and low standby power
The applications for the Electronic serie are, telecom supplies, electric substations etc. Industrial, domestic and consumer electronics
With the same footprint as a EI30 transformer, they will replace the 50 Hz Transformer, Fuse, Bridge Rectifier and Filtering Capacitor

Specificaties
Kenmerk Waarde
Secondary Voltage Rating 12V dc
Primary Voltage Rating 85 → 265 V ac, 85 → 370 V dc
Power Rating 3.2W
Number of Outputs 1
Mounting Type Through Hole
Length 31.7mm
Width 26.7mm
Depth 21.8mm
Dimensions 31.7 x 26.7 x 21.8mm
Maximum Temperature +70°C
Maximum Operating Frequency 440Hz
Minimum Operating Frequency 47Hz
Minimum Temperature -25°C
112 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
16,68
(excl. BTW)
20,18
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
16,68 €
10 - 24
9,26 €
25 +
8,34 €
Related Products
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Transformers forming the core of ...
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Transformers forming the core of ...
From Myrra the E25 and ETD Series flyback ...
Description:
From Myrra the E25 and ETD Series flyback transformers form the core of a switch mode power supply in association with a specialised circuit (VIPer, TOPSwitch, CoolSet, or control circuit + Mosfet.) Constructed with reinforced insulation, the E25 and ETD ...