Carroll & Meynell, 750VA CM1500WM0 Safety Transformer, 230V ac, 8.18A

Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: GB
Productomschrijving

Single Phase, 230Vac Input, 110Vac Output Transformers

High quality wall mounting safety isolating transformers designed to ensure safe electrical distribution for power tools etc in industrial, garage and other fixed installations.

Double wound
110V secondaries centre tapped to earth to minimise shock risk
Sheet steel IP22 type wall mounting enclosure
Re settable thermal cut out trip in primary circuit to prevent overload
Thermal safety overload fuse embedded into primary winding
20mm conduit entry on both sides of case

Note

Tool rating is defined in BSEN 61558-2-23 as 5 minutes on and 15 minutes off. Maximum output must not exceed 16A per socket outlet.

Approvals

8888

Standards

BSEN 61558-2-23

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac
Secondary Voltage Rating ±110V ac
Power Rating 750VA
Output Current 8.18A
Series CM1500WM0
Plug Type Hard Wire L-N-E
Weight 10.5kg
Length 200mm
Width 176mm
Depth 226mm
Dimensions 200 x 176 x 226mm
Mounting Type Wall Mount
Maximum Operating Frequency 60Hz
Minimum Operating Frequency 50Hz
6 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
181,39
(excl. BTW)
219,48
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
181,39 €
10 +
159,61 €
Related Products
The compact small tachometer TA327401 allows to read ...
Description:
The compact small tachometer TA327401 allows to read the frequency (max 100 kHz) of a signal from single or double (bidirectional encoder) input. 2 universal digital inputs are available (NPN/PNP/contact) for external commands like output activation or Hold/ Stop current ...
240 Vac 50HzDesigned to control the flow of ...
Description:
240 Vac 50HzDesigned to control the flow of water in iron and copper pipeNormally closedSpring return actionManual lever for filling/draining systemEnd switch for electrical control of pump and boilerPowerhead replaceable without draining downMotor changeable without replacing whole powerheadHigh close off ...
Designed to control the flow of water in ...
Description:
Designed to control the flow of water in small bore domestic central heating systems where both radiator and hot water cylinder circulation are pumped. 22mm compression fittingsDHW Circuit Port B; CH Circuit Port A240 Vac 50HzSpring return functionThree position operationManual ...
Applications include fridges, freezers, air conditioning and coolersDesigned ...
Description:
Applications include fridges, freezers, air conditioning and coolersDesigned to accurately stabilise large variations of mains voltageIncludes lightning surge/spike protectionDisconnects output when mains voltage is too high or too low3 minute wait period to allow compressor gases to neutralise before ...