Carroll & Meynell, 10kVA CM10K16 Single Phase Isolation Transformer, 230V ac, 2 x 32 A, 4 x 16 A

Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: GB
Productomschrijving

Single Phase 230Vac/Three Phase 400Vac Input, 110Vac Output, Isolating Transformers, Wall Mount

Safety isolating transformers for building and construction site applications having continuous ratings of 5kVA and 10kVA
Heavy duty sheet steel enclosure with lifting handles to withstand arduous building site conditions IP23 rating
Double wound with safety earth screen between windings
110V secondaries centre tapped to earth to minimise shock risk
Input and outputs protected by MCBs (Miniature Circuit Breakers)
Fitted with input gland for cable entry

Approvals

8888

Standards

BSEN 61558-2-23

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac
Secondary Voltage Rating ±55V ac
Power Rating 10kVA
Number of Phases 1
Output Current 2 x 32 A, 4 x 16 A
Series CM10K16
Plug Type Hard Wire L-N-E
Socket Type BS EN 60309
Weight 86kg
Length 390mm
Width 430mm
Depth 390mm
Dimensions 390 x 430 x 600mm
Mounting Type Free Standing
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 07/10/2020, met een levertijd van 2 à 3 werkdagen.
Prijs Each
907,34
(excl. BTW)
1.097,88
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
907,34 €
5 - 9
725,31 €
10 +
651,95 €
Related Products
Sine wave output voltageSelectable output frequency: 50/60HzHigh input-output ...
Description:
Sine wave output voltageSelectable output frequency: 50/60HzHigh input-output isolation 3000VrmsThree-phase synchronizationRemote inhibitInput and output alarm Railway version EN50155Fire and smoke: EN45545-2 approvedDNV GL maritime type aproved product.
Twin socket RCD circuit breaker simply replaces an ...
Description:
Twin socket RCD circuit breaker simply replaces an existing twin socket providing two protected switched socket outlets. The contacts break when power supply is temporarily lost. Power is immediately restored to the appliance/equipment at the end of a power failure. ...
Designed to provide protection against the risk of ...
Description:
Designed to provide protection against the risk of electrocution and fire hazards.Passive circuitry - power is restored immediately after a power failure.Active circuitry - power is only restored after device has been manually reset, thus protecting against equipment suddenly re-energising. ...
The micro-processor controlled single-phase power controller Jumo TYA ...
Description:
The micro-processor controlled single-phase power controller Jumo TYA 201 displays all parameters in a backlighted LCD display and is operated using the 4 keys on the front.SCR power controllers are employed where larger resistive and inductive loads have to be ...