Europa 2 Pole Type A, Type C Residual Current Circuit Breaker, 100A, 300mA

  • RS-stocknr. 916-0390
  • Fabrikantnummer EUR1100.300/2
  • Fabrikant Europa
Datasheets
Wetgeving en conformiteit
Conform
Productomschrijving

Europacomponents EUR1 Series RCCB

Europa Components EUR1 RCCB series provide ground fault protection by monitoring the leakage of current to ground when used with standard MCBs. The EUR1 series are compact DIN Rail-mounted RCCBs and feature a wide range of trip ratings to offer complete protection for commercial or industrial applications.

Compact AC DIN Rail mount 2 and 4 Pole RCCB’s
Protects against the effects of sinusoidal alternating earth fault currents
Protects against indirect contact, with additional protection against direct contact
Command and isolation of resistive and inductive circuits
Suitable for residential and commercial applications

Note

RCCBs are sensitive only to earth fault current (therefore they have to be connected in series with an MCB or a fuse to protect them against overcurrent and short circuits).

Europacomponents Circuit Protection Devices

Specificaties
Kenmerk Waarde
Current Rating 100A
Number of Poles 2
Trip Sensitivity 300mA
Tripping Characteristics Type A, Type C
Overall Depth 66mm
Overall Length 36mm
Application Residential
Reset Actuator Type Toggle Switch
Circuit Breaker Type RCCB
Rated AC Voltage 230 → 400V
Terminal Contact Type Screw
Special Features Earth Fault Safety Protection
Mounting Style DIN Rail Mount
1 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
94,39
(excl. BTW)
114,21
(incl. BTW)
Aantal stuks
Per stuk
1 +
94,39 €
Related Products
ID'clic differential plug-in switches, protected against inadvertent tripping. ...
Description:
ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters;Used for protection of "blue tariff" installations. Supply voltage 230 Vac.Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity.
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protection.The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
All-current-sensitive FI circuit breaker for detection of residual ...
Description:
All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currentsIncreased operating reliability in networks with capacitive impedances based on adapted actuation characteristicSwitch handle and test button may be locked via handle lockTime-delayed disconnect ...
The Acti 9 iID DIN rail RCCBs, are ...
Description:
The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service. Protection of persons against electric shock by direct ...