Europa 2 Pole Type A, Type C Residual Current Circuit Breaker, 25A, 100mA

  • RS-stocknr. 916-0375
  • Fabrikantnummer EUR125.100/2
  • Fabrikant Europa
Datasheets
Wetgeving en conformiteit
Conform
Productomschrijving

Europacomponents EUR1 Series RCCB

Europa Components EUR1 RCCB series provide ground fault protection by monitoring the leakage of current to ground when used with standard MCBs. The EUR1 series are compact DIN Rail-mounted RCCBs and feature a wide range of trip ratings to offer complete protection for commercial or industrial applications.

Compact AC DIN Rail mount 2 and 4 Pole RCCB’s
Protects against the effects of sinusoidal alternating earth fault currents
Protects against indirect contact, with additional protection against direct contact
Command and isolation of resistive and inductive circuits
Suitable for residential and commercial applications

Note

RCCBs are sensitive only to earth fault current (therefore they have to be connected in series with an MCB or a fuse to protect them against overcurrent and short circuits).

Europacomponents Circuit Protection Devices

Specificaties
Kenmerk Waarde
Current Rating 25A
Number of Poles 2
Trip Sensitivity 100mA
Tripping Characteristics Type A, Type C
Mounting Style DIN Rail Mount
Application Residential
Overall Length 36mm
Overall Depth 66mm
Reset Actuator Type Toggle Switch
Circuit Breaker Type RCCB
Rated AC Voltage 230 → 400V
Terminal Contact Type Screw
Special Features Earth Fault Safety Protection
1 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
3 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
45,51
(excl. BTW)
55,07
(incl. BTW)
Aantal stuks
Per stuk
1 +
45,51 €
Related Products
ID'clic differential plug-in switches, protected against inadvertent tripping. ...
Description:
ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters;Used for protection of "blue tariff" installations. Supply voltage 230 Vac.Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity.
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protection.The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
FI F202B+25/0,3 Residual Current Circuit Breaker. Compact and ...
Description:
FI F202B+25/0,3 Residual Current Circuit Breaker. Compact and functional designThe new F200 B RCCBs feature an innovative design that makes the products compact. Indeed, the two-pole device is the first one on the market that is built in just two ...
The RCCBs F200 series assures protection to people ...
Description:
The RCCBs F200 series assures protection to people and installations against fault current to earth. A large offer for standard instantaneous and selective AC and A types is completed with some configurations for special applications.