4P 25 A, RCD Switch, Trip Sensitivity 30mA, DIN Rail PXF PXF-A

  • RS-stocknr. 490-197
  • Fabrikantnummer 236772
  • Fabrikant Eaton
Datasheets
Wetgeving en conformiteit
N.v.t.
Land van herkomst: AT
Productomschrijving

Eaton RCD's - PXF-A Series

Introducing Eaton's range of PXF-A RCD, a professional and high-quality range of residual current devices. Providing complete protection, these RCD's have been created and designed to protect users from a fatal electric shock through the use of the automatic switch-off of electricity where there is a fault. These RCD's are commonly installed in applications where there are exposed wires, prone to overheating or earth faults.

Features & Benefits

• Fault current circuit breaker, conditionally current-proof up to 250 A
• Pulsed current sensitive, type A
• Contour and bus bar compatible with other P-Series devices
• Double terminal with lift / jaw top and bottom
• Free selection of rail arrangement top and bottom
• Free terminal space despite bus bar mounting
• Protects from special non-smoothened forms of DC fault currents
• Real contact position display
• Triggered state display through signal contact
• Retrofittable auxiliary switch
• Standards: IEC / EN 61008 and approvals are DIN VDE 0664 part 10

Specificaties
Kenmerk Waarde
Number of Poles 3 + N
Current Rating 25 A
Trip Sensitivity 30mA
Rated AC Voltage 400 V
Mounting Style DIN Rail
Range PXF
Series PXF-A
Tijdelijk niet op voorraad – nieuwe voorraad verwacht op 13/07/2020, met een levertijd van 1 werkdag.
Prijs Each
Was 85,90 €
43,42
(excl. BTW)
52,54
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
43,42 €
5 +
41,66 €
Related Products
New generation of Type 3 'MNT' surge protection ...
Description:
New generation of Type 3 'MNT' surge protection that provides high levels of safety. Protection that plugs into the mains socket for all devices supplied by the 230 V network.The MNT-TV-SAT B/F model is designed for audiovisual devices, and offers ...
Acti 9 iPRD DIN rail Surge Protector Devices ...
Description:
Acti 9 iPRD DIN rail Surge Protector Devices are geared to absolute safety and improved continuity of service. Maximum discharge current 8 to 65 kA Integrated disconnector for short-circuit current withstand, Isc, up to 25 kAMaximum steady state voltage, Uc ...
Output coupler Optocoupler 1 NO triac, Input 24 ...
Description:
Output coupler Optocoupler 1 NO triac, Input 24 V DC Output 20-264 V AC, 2 A Width 6.2 mm Spring-type terminal (push-in) Thermal current 2A.
The ABB RCBO is a 1P+N arc fault ...
Description:
The ABB RCBO is a 1P+N arc fault detection device (AFDD) with an integrated MCB in two modules. This provides protection against short-circuit currents, overload, earth arc faults, parallel arc faults and series arc faults. It is integrated with an ...