Better World
Schneider Electric RCBO, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type B, Acti 9 Range
- RS-stocknr.:
- 790-9452
- Fabrikantnummer:
- A9D56620
- Fabrikant:
- Schneider Electric
11 op voorraad - levertijd is 1 werkdag(en).
Toegevoegd
Prijs Per stuk
€ 199,29
(excl. BTW)
€ 241,14
(incl. BTW)
Aantal stuks | Per stuk |
1 + | € 199,29 |
Better World
Ons Better World assortiment bevat producten die het u gemakkelijk maken om een groenere productkeuze te maken waarop u kunt vertrouwen. Klik hier voor meer informatie.
- RS-stocknr.:
- 790-9452
- Fabrikantnummer:
- A9D56620
- Fabrikant:
- Schneider Electric
Wetgeving en conformiteit
Productomschrijving
Schneider Electric Residual Current Breaker With Over-Current, 20A, 30mA Trip Sensitivity - iDPN Series - A9D56620
Quickly identify the origin of an electrical fault with this residual current device (RCD) from Schneider Electric. It lets you know whether a fault is a result of a short circuit, overload or lack of insulation to save on diagnostics time. A VisiTrip feature instantly alerts you to an earth fault with a red bar that's easily seen. The unit's modular design makes it quick and easy to install with fewer connectors to wire. As this device precisely isolates a fault circuit, you can maintain continuity of service on all other circuits of the installation.
Features & Benefits
• Fully insulated front face for complete operator protection against electric shocks
• Robust design that's capable of withstanding extreme environments
• Supplied ready to connect to an Acti9 communication system for enhanced convenience
• Double DIN rail lockers mean there's no need to remove comb busbars during service for ease of use
• Robust design that's capable of withstanding extreme environments
• Supplied ready to connect to an Acti9 communication system for enhanced convenience
• Double DIN rail lockers mean there's no need to remove comb busbars during service for ease of use
Applications
• Cold storage units
• Hotels and commercial buildings
• Automated industries
• Hospitals
• Hotels and commercial buildings
• Automated industries
• Hospitals
Can I use this residual circuit breaker to protect a variable frequency device?
Yes, you can. This is because the residual circuit device includes an integrated miniature circuit breaker, making it perfect for applications where harmonic generating loads are present and where continuity of service is essential.
Specificaties
Kenmerk | Waarde |
---|---|
Current Rating | 20A |
Number of Poles | 1P+N |
Trip Sensitivity | 30mA |
Tripping Characteristics | Type B |
Range | Acti 9 |
Circuit Breaker Type | RCBO |
Series | iDPN |
Rated AC Voltage | 230V |
Mounting Style | DIN Rail Mount |
Earth Leakage Protection Type | A |
Better World Product | Yes |
Better World Verification | Green Premium |
Overall Dimensions | 36 x 73 x 85mm |
Tripping Mechanism | Thermal-Magnetic |
Breaking Capacity at Maximum Voltage Rating | 6 kA |
Overall Length | 36mm |
Overall Depth | 85mm |
Overall Width | 73mm |