i430-Flexi-TF-II 6000A Flexible AC Current Probe

The i430-Flexi-TF-II flexible AC current probe is optimized for current measurement on thick and hard to reach conductors. The i430-Flexi-TF-II is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II.

Measuring range: 0.5 to 6000 A ac
Bandwidth (-3 dB): 10 Hz to 10 kHz
Output signal: 86.6 mV at 1000A/50Hz (on 1 MΩ), 85.0 mV at 1000A/50Hz (on 50 kΩ)
Maximum non-destructive current: 100 kA (50/60 Hz)
Transducer length: 610 mm (24 in)
Transducer diameter: 7.5 mm (0.3 in)
Minimum bending radius: 38 mm (1.5 in)
Cable length from transducer to BNC: 2.5 m (98.4 in)
Complies with: IEC 61010-1: Pollution degree 2, IEC 61010-2-032: 1000V CAT III/ 600V CAT IV, IEC 61010-031

Supplied with

Instruction Sheet

Specificaties
Kenmerk Waarde
Accessory Type Flexible AC Current Probe
For Use With Fluke 433/434/435/434-II/435-II/437-II
3 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
1.248,00
(excl. BTW)
1.510,08
(incl. BTW)
Aantal stuks
Per stuk
1 +
1.248,00 €
Related Products
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10kHz bandwidthErgonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cableMax. conductor size ...
The i30 may be used in conjunction with ...
Description:
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. ...
Suitable for use with oscilloscopes, recorders and data ...
Description:
Suitable for use with oscilloscopes, recorders and data loggers a.c. coupled output (no d.c. offset) Voltage output of 3V full scale for each range Fits around conductors up to 160mm diameter Extended battery life and external power supply input Meets ...
Teledyne LeCroy current probes make accurate and reliable ...
Description:
Teledyne LeCroy current probes make accurate and reliable AC, DC and impulse current measurements without requiring the breaking of a circuit or the insertion of a shunt. This capability is based on a combination of Hall effect and transformer technology. ...