24V ac 1 Output Through Hole PCB Transformer, 5VA

  • RS-stocknr. 732-0427
  • Fabrikantnummer VC 5,0/1/24
  • Fabrikant Block
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

PCB Mount 230Vac Primary VC/VCM Series

Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)

Note

To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.

Standards

EN 61 558 IEC 61558

Approvals

ENEC, UL recognised

//media.rs-online.com/t_line/L347248-01.gif
//media.rs-online.com/t_line/L7320547-01.gif

Approvals

VDE; UL

Standards

EN 61 558; IEC 61558

Specificaties
Kenmerk Waarde
Secondary Voltage Rating 24V ac
Power Rating 5VA
Primary Voltage Rating 230V ac
Number of Outputs 1
Length 44mm
Width 37mm
Depth 33mm
Dimensions 44 x 37 x 33mm
Weight 190g
Mounting Type Through Hole
Maximum Temperature +50°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
24 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
5 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
4,95
(excl. BTW)
5,99
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
4,95 €
10 - 24
4,75 €
25 - 49
4,37 €
50 +
3,99 €
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range ...
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...
Secondary voltages are nominal load voltages on resistive ...
Description: