12V ac 1 Output Through Hole PCB Transformer, 2VA

  • RS-stocknr. 732-0360
  • Fabrikantnummer VB 2,0/1/12
  • Fabrikant Block
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

Transformers PCB Mount, Short Circuit Proof, VB & PT Series

230Va.c. 50 to 60Hz primary
Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval)
VB series (0.35 - 3.2VA) are inherently short circuit proof
PT series (4.5 - 22VA) are protected by internal PTC device
Compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
High efficiency and low temperature rise
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure boarding mounting on 4.5VA and above

Standards

EN 61558

Approvals

ENEC 10; UL recognised component

//media.rs-online.com/t_line/L7320525-01.gif

Approvals

VDE; UL

Standards

EN 61558

Specificaties
Kenmerk Waarde
Secondary Voltage Rating 12V ac
Power Rating 2VA
Primary Voltage Rating 230V ac
Number of Outputs 1
Length 32.3mm
Width 27.3mm
Depth 26.8mm
Dimensions 32.3 x 27.3 x 26.8mm
Weight 100g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
31 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
36 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
3,40
(excl. BTW)
4,11
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
3,40 €
10 - 24
3,21 €
25 - 49
2,96 €
50 +
2,70 €
Related Products
Multi-tapped secondary winding. Suitable for a wide range ...
Description:
Multi-tapped secondary winding. Suitable for a wide range of applications requiring selected secondary voltages. Double section bobbin constructionFully shrouded bobbinsFull varnish impregnationMulti-hole frame fixingSolder tag terminations100% electrical and flash testedTested in accordance with BS3535 and EN 60 742.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding ...
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings ...
Description:
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedHigh efficiency and ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.