12V ac 2 Output Through Hole PCB Transformer, 2.3VA

  • RS-stocknr. 667-5304
  • Fabrikantnummer AVB2.3/2/12
  • Fabrikant Block
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

Transformers PCB Mount, Short Circuit Proof, AVB Series

Dual 115Va.c. 50 to 60Hz primary
Twin secondary windings for series or parallel connection
AVB series are inherently short circuit proof compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
High efficiency and low temperature rise

Approvals

VDE 0570/EN 61 558, UL 506, CSA 22.2

Specificaties
Kenmerk Waarde
Secondary Voltage Rating 12V ac
Power Rating 2.3VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 32.3mm
Width 27.3mm
Depth 34mm
Dimensions 32.3 x 27.3 x 34mm
Weight 110g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
79 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
3,65
(excl. BTW)
4,42
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
3,65 €
10 - 49
3,21 €
50 - 99
3,07 €
100 - 199
2,99 €
200 +
2,92 €
Verpakkingsopties
Related Products
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz ...
Description:
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range ...
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
RS Pro PCB Standard transformers are low voltage ...
Description:
RS Pro PCB Standard transformers are low voltage mains transformers with a single 230 VAC 50/60Hz primary windingThese transformers have secondary windings suitable for series/ parallel connection to give a wide range of current options. They are 100% electric and ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...