6V ac 2 Output Through Hole PCB Transformer, 1VA

  • RS-stocknr. 173-9585
  • Fabrikantnummer 44055
  • Fabrikant Myrra
Datasheets
Wetgeving en conformiteit
N.v.t.
Land van herkomst: FR
Productomschrijving

Type EI 30 - 1 VA → 2.3 VA series 44000 transformers

From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable.

Features and Benefits:

• Professional safety transformers with insulation above 4000V.
• For installation on printed circuit boards (according to European grid).
• Coupling in series or parallel.
• Vacuum-filled with resin to ensure materials withstand aging.
• Unit and 100% control on automated line.
• Secondary voltages are nominal load voltages on resistive loads.

Standards

UL 94-V0; VDE 0551; IEC 742

Approvals

UL, VDE

Encapsulated – Toroidal

Note

Fixing screws not provided

Specificaties
Kenmerk Waarde
Secondary Voltage Rating 6V ac
Power Rating 1VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 32.6mm
Width 27.6mm
Depth 22.2mm
Dimensions 32.6 x 27.6 x 22.2mm
Weight 70g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
55 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
3,80
(excl. BTW)
4,60
(incl. BTW)
Aantal stuks
Per stuk
1 - 24
3,80 €
25 - 49
3,64 €
50 - 99
3,46 €
100 - 249
3,30 €
250 +
3,13 €
Related Products
The two independent secondary windings may be connected ...
Description:
The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Optional terminal shrouds for 75VA and 100VA(503-928).
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...