Productomschrijving

PCB Mounting Low Profile 115 / 230Vac Primary

Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection
Twin secondary windings for series or parallel connection
Low profile compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure board mounting
Standard: EN60742, VDE 0551, IEC 61558

Note

Transformer with 2 x 24V outputs are not VDE, SEV approved.

Standards

VD 61 558

//media.rs-online.com/t_line/L201683-01.gif
Specificaties
Kenmerk Waarde
Secondary Voltage Rating 15V ac
Power Rating 10VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 68mm
Width 22.8mm
Depth 57mm
Dimensions 68 x 22.8 x 57mm
Weight 280g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 11/08/2020, met een levertijd van 2 à 3 werkdagen.
Prijs Each (In a Tray of 20)
10,91
(excl. BTW)
13,20
(incl. BTW)
Aantal stuks
Per stuk
Per tray*
20 +
10,91 €
218,20 €
*prijsindicatie
Related Products
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Twin 115Va.c. 50/60Hz primary windings ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings ...
Description:
Dual 115Va.c. 50 to 60Hz primaryTwin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedHigh efficiency and ...