Tektronix Oscilloscope Module ADA400A

  • RS-stocknr. 349-8214
  • Fabrikantnummer ADA400A
  • Fabrikant Tektronix
Datasheets
Wetgeving en conformiteit
N.v.t.
Land van herkomst: US
Productomschrijving

Tektronix ADA400A 1 MHz Differential Preamplifier

The ADA400A Active Differential Preamplifier allows direct oscilloscope measurements of very low amplitude voltages and signals which are not ground referenced. The high impedance of both inputs eliminates the need to add additional ground points in the DUT, thereby avoiding circulating currents which disturb the measurement or the circuit.,The high gain and extremely high common mode rejection provide usable measurements of voltages as low as 5μV, even in high noise environments. Selectable bandwidth limiting reduces normal mode noise from digital logic, switch mode power supplies and line frequency sources. Adjustable differential offset allows the user to null out transducer bridge bias and galvanic potential from the test set-up. An "infinite impedance" mode can be selected in the two highest gain ranges allowing accurate measurements of signals with high source impedance. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBE® interface

10μV/div Sensitivity
Low-pass filter: 100Hz, 3kHz, 100Hz or Full (1 MHz)
Typically 100 dB CMRR DC to 10 kHz
Selectable Gain: 100, 10, 1 or 0.1
Accurately measures signal as small as 5uV
Integral Probe Power with TEKPROBE™BNC

Tektronix ADA400A 1 MHz Differential Preamplifier

10μV/div Sensitivity
Low Pass filters for 100Hz, 3kHz, 100Hz and Full (1 MHz)
Typically 100 dB CMRR DC to 10 kHz
Selectable Gain: 100, 10, 1 or 0.1
Accurately measures signal as small as 5uV
Integral Probe Power with TEKPROBE ™ BNC

The ADA400A Active Differential Preamplifier allows direct oscilloscope measurements of very low amplitude voltages and signals which are not ground referenced. The high impedance of both inputs eliminates the need to add additional ground points in the DUT, thereby avoiding circulating currents which disturb the measurement or the circuit.
The high gain and extremely high common mode rejection provide usable measurements of voltages as low as 5μV, even in high noise environments. Selectable bandwidth limiting reduces normal mode noise from digital logic, switch mode power supplies and line frequency sources. Adjustable differential offset allows the user to null out transducer bridge bias and galvanic potential from the test set-up. An "infinite impedance" mode can be selected in the two highest gain ranges allowing accurate measurements of signals with high source impedance. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBE® interface.

Specificaties
Kenmerk Waarde
For Use With TDS400 Series, TDS500 Series, TDS5000 Series, TDS600 Series, TDS700 Series, TDS7000 Series
Model Number p ADA400A
2 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
2.350,00
(excl. BTW)
2.843,50
(incl. BTW)
Aantal stuks
Per stuk
1 +
2.350,00 €
Let op:
dit artikel is voorzien van een UK Plug.
Related Products
Tektronix MSO/DPO2000 accessories include: analysis modules embedded serial ...
Description:
Tektronix MSO/DPO2000 accessories include: analysis modules embedded serial triggering DPO2EMBD ( 575-614 ), computer serial triggering DPO2COMP ( 575-563 ) and automotive serial triggering DPO2AUTO ( 575-573 ); video out port DPO2CONN ( 575-579 ); soft carrying case ACD2000 ( ...
Tektronix MSO/DPO2000 accessories include: analysis modules embedded serial ...
Description:
Tektronix MSO/DPO2000 accessories include: analysis modules embedded serial triggering DPO2EMBD ( 575-614 ), computer serial triggering DPO2COMP ( 575-563 ) and automotive serial triggering DPO2AUTO ( 575-573 ); video out port DPO2CONN ( 575-579 ); soft carrying case ACD2000 ( ...
Rohde & Schwarz Scope Rider RTH1004 offers the ...
Description:
Rohde & Schwarz Scope Rider RTH1004 offers the performance and capabilities of a laboratory oscilloscope together with the form factor and ruggedness of a battery-operated handheld device. Digital control signals can be analysed with the 8-bit logic interface that is ...
GPIB (IEEE -488.2) programmability: Full talk/listen modes; Control ...
Description:
GPIB (IEEE -488.2) programmability: Full talk/listen modes; Control of all modes, settings and measurementsVGA: Monitor output for direct display on large VGA-equipped monitors. DB-15 female connector, 31.6kHz sync rate, EIA RS-343A compliantRS-232-C interface programmability: Full talk/listen modes; Control of ...