Sick Vertical Mounting Level Radar 0-10 V, 4-20 mA Output IO-Link

  • RS-stocknr. 794-3383
  • Fabrikantnummer LFP1000-A4NMB
  • Fabrikant Sick
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

SICK Guided Radar Level Detection

A range of guided radar level detection units from SICK. Using TDR (time domain reflectrometry), time of flight technology these level sensors use contact type level measurement to detect and monitor levels in both water and oil based fluids. Offering accurate and reliable measurement that is unaffected by environmental and physical conditions such as temperature, pressure, agitated surfaces, viscosity or acidity. SICK’s range of guided radar level sensors can be mounted close to each other without crosstalk and accuracy is unaffected by deposit build-up on the probe.
LFP Inox models have been specifically designed for hygienic applications and are CIP and SIP resistant
(see stock numbers 794-3395, 794-3399, 794-3709)

Four button set-up
No requirement for calibration or re-calibration
3 in 1 Combination, Display, analog and binary outputs
Simultaneous level detection and continuous monitoring output capability
High Accuracy measurement in difficult conditions
Compact design
Rotatable housing
IP67 Rated enclosure
Probe length can be easily modified to suit application.
No moving parts

Specificaties
Kenmerk Waarde
Device Type Guided Radar
Mounting Type Vertical
Switch Output 0-10 V, 4-20 mA
Body Material PBT
Communication Protocol IO-LINK
Minimum Operating Temperature -20°C
Maximum Operating Temperature +100°C
Maximum Current 100 mA
Maximum Pressure 10bar
Gasket Material PTFE
Interface IO-Link
6 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
397,50
(excl. BTW)
480,98
(incl. BTW)
Aantal stuks
Per stuk
1 +
397,50 €
Related Products
Capacitive fill level switch with inverse frequency shift ...
Description:
Capacitive fill level switch with inverse frequency shift technologyConfigurable outputsSensitivity settingLED status displayVersion with connection cableFor detecting liquids, granulates, slurry, foam and separating layers in confined systems.
Rugged fill level measurement in fluid mediaSmall, compact ...
Description:
Rugged fill level measurement in fluid mediaSmall, compact design, no medium calibration requiredProcess temperature up to 55 °C, process pressure up to 16 barProcess connection G Highly medium resistant due to stain-less steel housing 1.4404, polysul-fone apexOutput available as PNP ...
Available in flying lead or M12 connector versions. ...
Description:
Available in flying lead or M12 connector versions. Cables are available for use with M12 connection versions. The switch action may be reversed by removing the float, inverting it, then refitting to the stem. These float switches have a switching ...
CE marked in compliance with relevant European Directives. ...
Description:
CE marked in compliance with relevant European Directives. Sensing range 2 to 10mm adjustable via a single turn potentiometerLED indication when activatedOutput: DC 100mA transistorPower ON delay; Max 40ms (No delay version), Max 5s (ON/OFF delay versions)Supply voltage; 5-30VdcNo load ...