TRACOPOWER TIM 2 DC-DC Converter, 15V dc/ 134mA Output, 9 → 18 V dc Input, 2W, Through Hole, +105°C Max Temp
- RS-stocknr.:
- 152-6547
- Fabrikantnummer:
- TIM 2-1213
- Fabrikant:
- TRACOPOWER
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 02/09/2024, met een levertijd van 2 à 3 werkdagen.
Prijs 1 tube 10
€ 257,34
(excl. BTW)
€ 311,38
(incl. BTW)
Tube(s) | Per tube | Per stuk* |
1 - 4 | € 257,34 | € 25,734 |
5 - 9 | € 249,62 | € 24,962 |
10 - 24 | € 241,90 | € 24,19 |
25 - 49 | € 231,61 | € 23,161 |
50 + | € 221,31 | € 22,131 |
*prijsindicatie |
- RS-stocknr.:
- 152-6547
- Fabrikantnummer:
- TIM 2-1213
- Fabrikant:
- TRACOPOWER
Wetgeving en conformiteit
- Land van herkomst:
- TW
Productomschrijving
Medical/Reinforced I/O-Isolation DC/DC Converters 2 - 30 Watt
2 Watt DC/DC converter in DIP-16 package
Certification to IEC/ES 60601-1 3rd edition for 2 x MOPP
I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Risk management file acc. ISO 14971
Quality to ISO 13485, IPC-A-610 level 3
5-year product warranty
2:1 input voltage with extended low input range:4.5-12, 9-18, 18-36, 36-75
Output voltages:5.0, 12, 15, 24, ±12, ±15 VDC
I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Low leakage current
Input filter to meet EN55022 class A
I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Risk management file acc. ISO 14971
Quality to ISO 13485, IPC-A-610 level 3
5-year product warranty
2:1 input voltage with extended low input range:4.5-12, 9-18, 18-36, 36-75
Output voltages:5.0, 12, 15, 24, ±12, ±15 VDC
I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Low leakage current
Input filter to meet EN55022 class A
Specificaties
Kenmerk | Waarde |
---|---|
Output Voltage | 15V dc |
Input Voltage Range | 9 → 18 V dc |
Power Rating | 2W |
Input Voltage Nominal | 12 V dc |
Output Current | 134mA |
Mounting Type | Through Hole |
Isolated | Yes |
Number of Outputs | 1 |
Package | DIP 16 |
Isolation Voltage | 5kV ac |
Depth | 10.2mm |
Length | 24.3mm |
Width | 14.4mm |
Series | TIM 2 |
Load Regulation | 0.01 |
Minimum Temperature | -40°C |
Medical Approved | Yes |
Maximum Temperature | +105°C |
Efficiency | 82% |
Standards Met | AAMI/ANSI ES 60601-1, EN 55022, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, IEC/EN 60601-1, MIL-STD-810F |