Testo 835-T2 Infrared Thermometer With RS Calibration

  • RS-stocknr. 776-4903
  • Fabrikantnummer 0560 8352
  • Fabrikant Testo
Datasheets
Wetgeving en conformiteit
N.v.t.
Land van herkomst: CN
Productomschrijving

Testo 835 T-2 Infrared Thermometer

For non-contact temperature measurements, the Testo 835 T-2 is specifically designed for trade and industry. Featuring a new processor it has better resolution and makes precise IR measurements possible. The 4-point laser thermometer has spot marking and 50:1 distance-to-spot ratio making the testing of small objects possible.

With a pistol style ergonomic design it also features adjustable limit values and alarm function. The T2 can measure precise temperatures of up to 1500°C from a safe distance with it's extended temperature measuring range.

Features and Benefits:

• -10°C to 1500°C temperature range
• Fast readings
• Audible and visual alarms
• Back-lit display
• Adjustable emissivity 0.10 to 1.00

FAQ's

Are infrared thermometers dangerous?

Infrared thermometers are not harmful, they do not emit radiation, only measure it like a digital camera.

How accurate are infrared thermometers?

The majority of IR thermometers have a measurement error specification, which shows their best accuracy. The surface being measured can also affect accuracy. Reflective objects result in lower measurements than the actual temperature, whilst non-reflective surfaces give higher measurement. The emissivity of a surface is how effective it is at emitting energy as thermal radiation, as such some IR thermometers have adjustable emissivity settings.

Distance to spot ratio is also essential in providing accurate temperature measurements, if an infrared thermometer is too close to its target area, heat can build up in the device. This can give false readings or damage the temperature sensors, therefore it is essential to always follow a manufacturers guidelines.

Supplied with

3 batteries Type AA and calibration protocol

Specificaties
Kenmerk Waarde
Absolute Maximum Temperature Measurement +1500°C
Temperature Scale Centigrade
Calibrated RSCAL
Distance to Spot Ratio 50:1
Best Accuracy ±1 %, ±2.0 °C
Emissivity 0.1 → 1
Model Number p 835-T2
Resolution 0.1 °C, 1 °C
Data Storage Yes
Length 193mm
Width 166mm
Height 63mm
Dimensions 193 x 166 x 63mm
Weight 514g
Tijdelijk niet op voorraad – nieuwe voorraad verwacht op 28/04/2020, met een levertijd van 1 werkdag.
Prijs Each
Was 787,00 €
499,00
(excl. BTW)
603,79
(incl. BTW)
Aantal stuks
Per stuk
1 +
499,00 €
Related Products
A multipurpose thermometer combining infrared and contact capability, ...
Description:
A multipurpose thermometer combining infrared and contact capability, the Fluke 566 is straight forward and menu driven. Complex temperature measurement is made easy, the contact, non-contact combination provide the optimal measurement solution. Featuring quick navigation, emissivity adjustment and data logging ...
Temperature variances can indicate common mechanical and electrical ...
Description:
Temperature variances can indicate common mechanical and electrical problems. These can be diagnosed faster, safer and easier with the AutoPro ™ non-contact infrared thermometer, specifically designed for the automotive professional. Features SmartSight™ - 2 lasers merge into a single laser ...
Small, exceptional accurate temperature readings and easy to ...
Description:
Small, exceptional accurate temperature readings and easy to use, Fluke's MAX series are precise and designed to resist a 3 meter drop. IP54 rated for dust and water resistance, these non-contact thermometers are highly durable and robust for tough environments. ...
The IR-730 Infrared Thermometer is specifically designed for ...
Description:
The IR-730 Infrared Thermometer is specifically designed for HVAC/R, electrical, industrial maintenance, automotive as well as quality control and fire prevention applications. 30:1 Distance to Spot Ratio Temp Range of -32°C to 1250°C Precision accuracy and rapid response time Laser ...