2 x 36 W, Bulkhead Light Fitting, 1, 2, 21, 22, Fluorescent, Temp T4, T5

  • RS-stocknr. 781-2572
  • Fabrikantnummer EVS240EMA
  • Fabrikant DTS
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: FR
Productomschrijving

Emergency Hazardous Fitting, Zone 1, 2, 21 & 22 Ex-e

The EVS-EMA Series from DTS is an emergency lighting hazardous area Ex e fluorescent luminaries, is designed for use in Zone 1, 2, 21, and 22 areas, allowing the same emergency luminaries to be used across the whole of a hazardous area site at the same time meeting the requirements of the evacuation standards. The EVS-EMA ATEX luminaries combine high quality with a large range of features.

Main body constructed of a GRP for high impact strength
Polycarbonate diffuser to resist harsh and corrosive environments
Electronic ballast 220- 240V 50/60Hz
Battery duration 3 hours
Emergency fluorescent fitting with automatic test 5 wire Loop
Clear LED for easy visual battery inspection
Automatic switch off upon opening for safe maintenance
All components mounted on hinged and removable gear tray
Easy access for installation and maintenance
Lamp not included

Approvals

EN60079-.0, 60079-1, 60079-5, 60079-7, 61241-1
LCIE 11 ATEX 3065X
IEC Ex LCI 11,0053X
Ex II 2 G
Ex de IIC T4 Gb for ≤ -40°C to ≤ +60°C
Ex de IIC T5 Gb for ≤ -40°C to ≤ +35°C
Ex II 2 D, Ex tb IIIC T85°C Db IP6x
IEC 60529 (2001) IP66

Supplied with

One nylon M20 cable gland cable (6-12mm), two M20 nylon plugs & two zinc plated steel brackets for ceiling mounting (V015)

Emergency Light Fittings

There are two basic types of emergency lighting luminaires - maintained and non-maintained.
Maintained, these luminaires have the advantage of being able to be switched between the maintained function (lamp illuminated at all times) and non-maintained (lamp off until power supply fails), making them ideal for applications such as corridors, workshops and permanently illuminated emergency exit signs. The maintained luminaires also have the facility of being switched in banks of up to ten units.

Non-maintained, these luminaires are only illuminated on a failure of the mains supply. Ideal for emergency exits, switchrooms and storage areas.

Specificaties
Kenmerk Waarde
Type Bulkhead
Zone Classification 1, 2, 21, 22
Temperature Classification T4, T5
Wattage 2 x 36 W
Lamp Type Fluorescent
Individual Lamp Wattage 36W
Number of Lamps 2
Hazardous Area Certification ATEX
tijdelijk niet op voorraad – nieuwe voorraad verwacht op 12/03/2020, met een levertijd van 2 à 3 werkdagen.
Prijs Each
828,16
(excl. BTW)
1.002,07
(incl. BTW)
Aantal stuks
Per stuk
1 +
828,16 €
Related Products
The Sylvania 605 mm LED batten is the ...
Description:
The Sylvania 605 mm LED batten is the perfect replacement for traditional T8 battens, with exceptional energy savings through lower power consumption. This batten has the added feature of being DALI dimmable control. Led lamp technology allows instant light with ...
Easy adjustment of sensor range, daylight detection and ...
Description:
Easy adjustment of sensor range, daylight detection and hold timeHigh luminous efficacyEnergy savings of up to 55 % compared to luminaires that use CFLEasy and quick installationVery homogenous lightClear cover protects the reflector against dust and contact3 years ... frequency ...
Slim profileResistance against vandalismHigh luminous efficacyVery homogenous lightLED ...
Description:
Slim profileResistance against vandalismHigh luminous efficacyVery homogenous lightLED protected for safe installation5 years ... areasBeam angle: 120°Type of protection: IP65Impact resistance: IK10Housing and cover made from polycarbonateGlow Wire Test according to IEC 60695-2-12: 850 °CThrough-wiring possible.
Floodlight- 105W LED - wide beam - with ...
Description: