Lapp Fixed Installation Power Cable - NYY-J
From Lapp, this NYY-J cable is a widely-used power and control cable that is often found in domestic and commercial electrical wiring. As well as being used in fixed installations, the cable is designed to be used for direct burial, and burial in concrete, providing the operating temperature is adhered to.
The cable is bare copper single core with PVC with a filling compounds over the core assembly. The PVC sheath is flame retardant and robust, allowing the cable to be used in dry, damp and wet interiors. NYY-J cable is also able very resistant to UV, and so is able to be used outdoors.
Features and Benefits
Bare copper conductors
PVC-based outer sheath
Suitable for outdoor use
Flame-retardant according IEC 60332-1-2
Above, below, flush and recess routing
Operating temperature during installation: -5°C to +50°C
Operating temperature in a fixed installation: -40°C to +70°C
Applications
Able to be installed in open air and underground, NYY-J cable presents a versatile power cable that should be used in where the risk of mechanical damage is unlikely. As such it can be used in brickwork and concrete, proving the concrete is not shaken, vibrated or compressed. Lapp NYY-J able is often used in;
Power stations
Distributor boards
Subscriber networks
The cable is bare copper single core with PVC with a filling compounds over the core assembly. The PVC sheath is flame retardant and robust, allowing the cable to be used in dry, damp and wet interiors. NYY-J cable is also able very resistant to UV, and so is able to be used outdoors.
Features and Benefits
Bare copper conductors
PVC-based outer sheath
Suitable for outdoor use
Flame-retardant according IEC 60332-1-2
Above, below, flush and recess routing
Operating temperature during installation: -5°C to +50°C
Operating temperature in a fixed installation: -40°C to +70°C
Applications
Able to be installed in open air and underground, NYY-J cable presents a versatile power cable that should be used in where the risk of mechanical damage is unlikely. As such it can be used in brickwork and concrete, proving the concrete is not shaken, vibrated or compressed. Lapp NYY-J able is often used in;
Power stations
Distributor boards
Subscriber networks
Lapp NYY-J Series Power Cable, Bare Copper Conductor Material, 50m Length - 15500103
This power cable by Lapp with 13 AWG provides reliable and efficient electrical connectivity for various applications. With a cross-sectional area of 2.5mm² and solid core strand, the cable ensures optimal performance and durability in different environments.
Features & Benefits
• Bare copper conductor ensures high conductivity and minimal signal loss
• Flame retardant properties provide safety in case of fire incidents
• PVC insulation offers protection against external elements and harsh conditions
• Eca CPR certification ensures compliance with safety standards
• 1 kV voltage rating enables versatile usage in different settings.
• Flame retardant properties provide safety in case of fire incidents
• PVC insulation offers protection against external elements and harsh conditions
• Eca CPR certification ensures compliance with safety standards
• 1 kV voltage rating enables versatile usage in different settings.
Applications
• Ideal for fixed installations in both indoor and outdoor environments
• Suitable for burial without additional protection, meeting VDE standard requirements
• Suitable for burial without additional protection, meeting VDE standard requirements
Can it be used outdoors?
Yes, it is suitable for outdoor applications due to its durable construction.
Will it provide reliable performance in harsh conditions?
Yes, the flame-retardant design ensures safety and efficiency in all settings.
Is the cable suitable for burial?
Yes, it is designed for burial without additional protection, meeting industry standards.
Power Cable
Specificaties
Kenmerk | Waarde |
---|---|
Cross Sectional Area | 2.5 mm² |
Number of Cores | 3 |
Sheath Colour | Black |
Length | 50m |
Current Rating | 25 A |
Outer Diameter | 13mm |
Sheath Material | PVC |
CPR Certification | Eca |
Voltage Rating | 1 kV, 600 V |
Conductor Strand Type | Solid |
Standards Met | Euroclass Eca |
Maximum Operating Temperature | +50°C |
Core Strands | 1.78 mm |
Size of Strands | 1.78 mm |
Series | NYY-J |
Conductor Material | Bare Copper |
Minimum Operating Temperature | -5°C |
Fire Behaviour | Flame Retardant |
Insulation Material | PVC |
Conductor Resistance | 7.41 Ω/km |