Block 3000 (CosΦ=1) VA, 8500 (cosΦ=0.5) VA Isolating Transformer, 475V ac, 500V ac, 525V ac Primary

  • RS-stocknr. 903-9864
  • Fabrikantnummer TT1 3-5-23
  • Fabrikant Block
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

TT1 Series Isolating Transformer

High-quality multi-purpose panel mount isolating transformers from the Block TT1 series. The transformers are designed for the safe isolation of the input and output sides. They can be used to set up protective separation as a protective measure.

Features and Benefits:

Safe galvanic isolation
Integrated crane eyes
Non-slip terminals Corrosion protections and low noise
Horizontal design ensures space saving

Specificaties
Kenmerk Waarde
Primary Voltage Rating 475V ac, 500V ac, 525V ac
Secondary Voltage Rating 2 x 115V ac
Power Rating 3000 (Cosφ=1) VA, 8500 (cosφ=0.5) VA
Mounting Type Fixing Rail
Length 275mm
Dimensions 200 x 275 x 165mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +40°C
1 op voorraad - levertijd is 1 werkdag(en).
Prijs Each
359,98
(excl. BTW)
435,58
(incl. BTW)
Aantal stuks
Per stuk
1 +
359,98 €
Related Products
BLOCK STEU series isolating transformers with a dual ...
Description:
BLOCK STEU series isolating transformers with a dual input of 230 and 400 Vac, These safety transformers have a high performance for the volume due to their compact design. The transformers are quick to cable up due to the use ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Short-circuit proof safety isolating transformersResin encapsulated transformersStable plastic ...
Description:
Short-circuit proof safety isolating transformersResin encapsulated transformersStable plastic enclosureIntegrated fuse protection and thermal cut-out against overloading and short circuitsScrew-type terminals for the connecting leads on input and output sideMeet the requirements of IEC61 558, EN61 558, ...
Low inrush current control, safety isolating and isolating ...
Description:
Low inrush current control, safety isolating and isolating transformerScrew type terminals, fitted with screw mounting bracketsCompact design with ±20V tappings on the primary windingFor use up to +40°C ambient maximum.