Siemens 0.4kVA Isolating Transformer, 230V ac Primary 1 x, 24V ac Secondary

  • RS-stocknr. 480-4929
  • Fabrikantnummer 4AM4642-4TN00-0EA0
  • Fabrikant Siemens
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: CZ
Productomschrijving

Control transformers, 1-phase, 4AM Series

Use as power, safety or displacement transformers in accordance with the applicable EN norm
High short-term performance
Low switch-on power (switch-on rush)
Protect against short circuits and overloading with motor protection switches on main side
Electrically isolated coils
Screw terminal connectors

Standards

EN 61 558-2-1, EN 61 558-2-2, EN 61 558-2-4 (at U SEC > 50 V AC), EN 61 558-2-6,
VDE 0570

Approvals

CE, UL

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac
Secondary Voltage Rating 24V ac
Power Rating 0.4kVA
Mounting Type DIN Rail
Number of Outputs 1
Length 121mm
Width 122mm
Depth 114mm
Dimensions 121 x 122 x 114mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +40°C
Weight 5.4kg
Tijdelijk niet op voorraad – nieuwe voorraad verwacht op 07/11/2019, met een levertijd van 1 werkdag.
Prijs Each
170,24
(excl. BTW)
205,99
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
170,24 €
5 - 9
156,04 €
10 - 24
144,05 €
25 - 49
133,99 €
50 +
131,47 €
Related Products
Compact, open type control panel transformerFully shrouded screw ...
Description:
Compact, open type control panel transformerFully shrouded screw terminals with permanent markingDetailed product specification permanently marked on front of unitVA ratings compatible with available protection devicesDual standard primary winding 230 / 400Vac.
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
High quality safety and isolating transformers designed for ...
Description:
High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual secondaries are centre tapped. Earth terminal provided ...
Universal input transformers are designed for worldwide usage ...
Description:
Universal input transformers are designed for worldwide usage and fulfill the requirements for control safety isolating and isolating transformers suitable for DIN Rail mounting (to 250VA) or footplate mounting (all types) and the use of cage clamp terminals makes installation ...