Siemens 2.5kVA Isolating Transformer, 230V ac Primary 1 x, 230V ac Secondary

  • RS-stocknr. 480-4777
  • Fabrikantnummer 4AM6542-4TT10-0FA0
  • Fabrikant Siemens
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

Control transformers, 1-phase, 4AM Series

Use as power, safety or displacement transformers in accordance with the applicable EN norm
High short-term performance
Low switch-on power (switch-on rush)
Protect against short circuits and overloading with motor protection switches on main side
Electrically isolated coils
Screw terminal connectors

Standards

EN 61 558-2-1, EN 61 558-2-2, EN 61 558-2-4 (at U SEC > 50 V AC), EN 61 558-2-6,
VDE 0570

Approvals

CE, UL

Specificaties
Kenmerk Waarde
Primary Voltage Rating 230V ac
Secondary Voltage Rating 230V ac
Power Rating 2.5kVA
Mounting Type DIN Rail
Number of Outputs 1
Length 180mm
Width 194mm
Depth 178mm
Dimensions 180 x 194 x 178mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +40°C
Weight 29kg
2 op voorraad - levertijd is 1 werkdag(en)
Prijs Each
722,30
(excl. BTW)
873,98
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
722,30 €
5 - 9
693,79 €
10 +
667,44 €
Related Products
This range of covered (up to 320 VA) ...
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
High quality safety and isolating transformers designed for ...
Description:
High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual secondaries are centre tapped. Earth terminal provided ...
RS Pro high-quality panel isolation transformers are designed ...
Description:
RS Pro high-quality panel isolation transformers are designed for use in general applications. These single phase transformers feature screw connectors for multiple input and brackets for screw fixing or for DIN Rails. They have a standard primary winding 0-230-400VAC with ...
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. Single-phase single-winding safety and isolation transformers.Able to supply higher powers on occasion.Feature a panel display to reduce ESD. Screw termination.Plate mounting.