Productomschrijving

ABT7ESM0 series economic transformer

This range of single-phase single-winding safety and isolation transformer is primarily designed for use in repetitive applications.
ABT 7 series transformers provide enhanced electrical isolation between the mains supply and the application. The whole range features an electrostatic screen to limit the spread of electromagnetic interference and improve user safety.

Laminated Frame 230Vac Primary 75VA to 200VA (Multi Tapped)

Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding.

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Multi-hole frame fixing
Solder tag terminations
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Specificaties
Kenmerk Waarde
Primary Voltage Rating 215V ac, 230V ac, 245V ac
Secondary Voltage Rating 24V ac
Power Rating 250VA
Mounting Type Chassis
Number of Outputs 1
Length 98mm
Width 106mm
Depth 105mm
Dimensions 98 x 106 x 105mm
Minimum Operating Frequency 47Hz
Maximum Operating Frequency 63Hz
Minimum Temperature -20°C
Maximum Temperature +40°C
Weight 3.5kg
1 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
2 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
67,45
(excl. BTW)
81,61
(incl. BTW)
Aantal stuks
Per stuk
1 +
67,45 €
Related Products
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. Single-phase single-winding safety and isolation transformers.Able to supply higher powers on occasion.Feature a panel display to reduce ESD. Screw termination.Plate mounting.
Single-phase control and signalling transformers (50 → 60 ...
Description:
Single-phase control and signalling transformers (50 → 60 Hz - class 1).Active parts protected by cover up to 1000 VA.Mounting on full or perforated platinum, or rail according to power.Direct mounting possible on symmetrical DIN rail up to 250 VA.More ...