LEM HASS Series Open Loop Current Sensor, ±900A nominal current

  • RS-stocknr. 521-936
  • Fabrikantnummer HASS 400-S
  • Fabrikant LEM
Datasheets
Wetgeving en conformiteit
Conform
Productomschrijving

HASS Series

Open loop current transducer with Hall effect measuring principle
For measuring DC, AC and pulse currents
With galvanic separation between primary and secondary circuits
Unipolar voltage supply
Fixed offset voltage with corresponding amplification
Housing made from insulating, self-extinguishing material UL94-V0

Approvals

CE

Specificaties
Kenmerk Waarde
Sensor Technology Open Loop
Nominal Current ±900A
Supply Voltage 5 V
Sensor Type Hall Effect
Mounting Type Panel Mount
Frequency Bandwidth DC to 50 kHz
Bore Size 20.4 x 10.4mm
Accuracy ±1 %
Minimum Operating Temperature -40°C
Series HASS
Maximum Operating Temperature +85°C
Depth 30mm
Height 30mm
Width 40mm
25 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
169 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
16,44
(excl. BTW)
19,89
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
16,44 €
5 - 9
15,95 €
10 +
15,43 €
Related Products
Measurement of ac, dc and pulsed currentGalvanic isolation ...
Description:
Measurement of ac, dc and pulsed currentGalvanic isolation between power and measuring circuitsBody material plastic to UL94-V0PCB mountingThese transducers comply with EN 50178.
Current sensors for electronic measurement of alternating, direct, ...
Description:
Current sensors for electronic measurement of alternating, direct, pulse and mixed currents with galvanic insulation between the primary circuit (strong current) and secondary circuit (electronic circuit).Hall Effect measuring principle.Used with AC variable speed drives, static converters for DC motor drives, ...
Open Loop Hall Effect current transducers with integral ...
Description:
Open Loop Hall Effect current transducers with integral primary connections for the accurate measurement of current. Open Loop (low power consumption)AC,DC, and mixed signal measurementExtended measuring range (3xlpn)Small sizeHX 03-20 (23.5x15.8x19mm)HX 25-50 (20x19x15.4mm)Multi turn PrimaryUnipolar power supply ...
Closed Loop Hall Effect transducers for the accurate ...
Description:
Closed Loop Hall Effect transducers for the accurate measurement of current. The ASIC based transducer offers a ref in/out pin allowing the user to trim out offsets. AC/DC, and mixed current measurementClosed Loop, high accuracy (better than 1%)Unipolar 5V supply ...