LEM LAX Series Closed Loop Current Sensor, 0 → 160A nominal current, 50mA output current

  • RS-stocknr. 497-401
  • Fabrikantnummer LAX 100-NP
  • Fabrikant LEM
Datasheets
Wetgeving en conformiteit
Conform
Productomschrijving

LAX 100-NP Current Sensor

Small size Hall Effect sensor for fitting to printed circuits to measure currents up to 100 A RMS.
Current measurements of up to 16 A; 25 A; 33 A; 50 A or 100 A RMS based on primary connections made on the printed circuit.
This sensor is suitable for industrial applications such as variable speed controls, continuous power supplies (UPS) and cut-out power supplies (SMPS).
(L= 32 mm W = 27 mm H = 16.35 mm).

//media.rs-online.com/t_line/L0497401-10.gif
Specificaties
Kenmerk Waarde
Sensor Technology Closed Loop
Nominal Current 0 → 160A
Output Current Range 50mA
Supply Voltage 11.4 → 15.75 V
Sensor Type Hall Effect
Mounting Type PCB Mount
Frequency Bandwidth >300 kHz
Accuracy ±0.91 %
Series LAX
Minimum Operating Temperature -40°C
Maximum Operating Temperature +85°C
Depth 16.35mm
Height 32mm
Width 25.5mm
8 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
58 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
18,50
(excl. BTW)
22,38
(incl. BTW)
Aantal stuks
Per stuk
1 - 4
18,50 €
5 - 9
17,93 €
10 +
17,35 €
Related Products
The optional holding device ensures the Rogowski coil ...
Description:
The optional holding device ensures the Rogowski coil is securely seated on busbars that are 5 ... 10 mm thick. During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically.
Single-pole Hall effect current transducersMeasurement of inserted conductorVoltage ...
Description:
Single-pole Hall effect current transducersMeasurement of inserted conductorVoltage output, Vout = ±4VCapable of measuring complex signalsExcellent precision and good linearityLow temperature driftBody material Plastic; Polycarbonate PBTOperating Temperature Range -10 to +80°CSecondary connector: stock no. 543-7738.
AC / DC transformer with integrated signal preparationMeasures ...
Description:
AC / DC transformer with integrated signal preparationMeasures currents with VFD and SCR wavelengthElectrical isolationActual output; voltage or currentNo excess lossesCable entry to 32 mm ØSimple installation.
MACX MCR-SL-CAC series current measuring transducers. 3 way ...
Description:
MACX MCR-SL-CAC series current measuring transducers. 3 way isolationInput/output signal can be configured using the DIP switchOperating state indication via LEDScrew terminal block.