RS PRO 50VA 2 Output Chassis Mounting Transformer, 24V ac

Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: PL
Productomschrijving

Chassis Mount Clamp & Frame Construction 115/230Vac Primary Transformer

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps 6VA to 50VA
Multi-hole frame fixing 100VA
Solder tag terminations
Optional terminal shrouds
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Note

Suitable transformer shrouds: 6VA = 503-912 ; 12 & 20VA = 504-004 ; 50, 75 & 100VA = 503-928

Approvals

8888

Standards

BS3535; EN 60 742

Open Laminated Clamp & Frame 115-230Vac Primary 6VA to 100VA

Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Specificaties
Kenmerk Waarde
Primary Voltage Rating 115V ac, 230V ac
Secondary Voltage Rating 24V ac
Power Rating 50VA
Number of Outputs 2
Mounting Type Clamp Mount
Length 79mm
Width 62mm
Depth 65mm
Dimensions 79 x 62 x 65mm
Fixing Hole Diameter 4.7 x 9.5mm
Weight 1kg
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
1 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
74 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
21,32
(excl. BTW)
25,80
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
21,32 €
10 - 24
19,42 €
25 - 49
17,88 €
50 - 99
15,25 €
100 +
13,73 €
Related Products
The two independent secondary windings may be connected ...
Description:
The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Optional terminal shrouds for 75VA and 100VA(503-928).
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Va.c. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
PCB mounting mains transformers with a single 230Va.c. ...
Description:
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Twin 115Va.c. 50/60Hz primary windings ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.