RS PRO 50VA 2 Output Chassis Mounting Transformer, 24V ac

Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: PL
Productomschrijving

Chassis Mount Clamp & Frame Construction 115/230Vac Primary Transformer

Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps 6VA to 50VA
Multi-hole frame fixing 100VA
Solder tag terminations
Optional terminal shrouds
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

Note

Suitable transformer shrouds: 6VA = 503-912 ; 12 & 20VA = 504-004 ; 50, 75 & 100VA = 503-928

Approvals

8888

Standards

BS3535; EN 60 742

Open Laminated Clamp & Frame 115-230Vac Primary 6VA to 100VA

Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Specificaties
Kenmerk Waarde
Primary Voltage Rating 115V ac, 230V ac
Secondary Voltage Rating 24V ac
Power Rating 50VA
Number of Outputs 2
Mounting Type Clamp Mount
Length 79mm
Width 62mm
Depth 65mm
Dimensions 79 x 62 x 65mm
Fixing Hole Diameter 4.7 x 9.5mm
Weight 1kg
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
8 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
112 op voorraad - levertijd is 1 werkdag(en) (UK-voorraad)
Prijs Each
21,32
(excl. BTW)
25,80
(incl. BTW)
Aantal stuks
Per stuk
1 - 9
21,32 €
10 - 24
19,42 €
25 - 49
17,88 €
50 - 99
15,25 €
100 +
13,73 €
Related Products
The two independent secondary windings may be connected ...
Description:
The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Optional terminal shrouds for 75VA and 100VA(503-928).
Chassis mounting frame construction low voltage mains transformers ...
Description:
Chassis mounting frame construction low voltage mains transformers with a single 230Vac 50/60Hz primary winding. Single-phase single-winding safety and isolation transformers.Able to supply higher powers on occasion.Feature a panel display to reduce ESD. Screw termination.Plate mounting.
Single-phase control and signalling transformers (50 → 60 ...
Description:
Single-phase control and signalling transformers (50 → 60 Hz - class 1).Active parts protected by cover up to 1000 VA.Mounting on full or perforated platinum, or rail according to power.Direct mounting possible on symmetrical DIN rail up to 250 VA.More ...
Twin 115Va.c. 50/60Hz primary windings which may be ...
Description:
Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operationFully shrouded bobbins100% electrical and flash testedTested in accordance with BS3535 and EN 60 742.