Siemens 80A 2 NH Centred Tag Fuse, gG, 500V ac

  • RS-stocknr. 397-575
  • Fabrikantnummer 3NA3224
  • Fabrikant Siemens
Datasheets
Wetgeving en conformiteit
N.v.t.
Land van herkomst: GR
Productomschrijving

NH Fuse Links, 3NA3 Series, Size 2, Type gG

NH fuse links with front indicator
The front-face red indicator signals when the fuse cuts out
Operating class gG (for cable and line protection)
For selective line protection and system protection in functional building, industry and power supply companies

Standards

IEC 60269-1, IEC 60269-2, EN 60269-1

Approvals

DIN VDE 0636, DIN VDE 0636-2, CSA 22.2 No. 106

Approvals

DIN VDE 0636, DIN VDE 0636-2, CSA 22.2 No. 106

Standards

IEC 60269-1, IEC 60269-2, EN 60269-1

Specificaties
Kenmerk Waarde
Fuse Standard CSA 22.2 No.106 File No. 1710842, DINVDE 0636, DINVDE 0636-2, EN 60269-1, IEC 60269-1, IEC 60269-2
Fuse Size 2
Current Rating 80 A
Voltage Rating 500 V ac
High Rupture Capacity Yes
Overall Length 151mm
Body Width 47mm
Body Length 75mm
Application Category GG
Fuse Type NH
6 op voorraad - levertijd is 1 werkdag(en)
Prijs Each (In a Pack of 3)
13,397
(excl. BTW)
16,21
(incl. BTW)
Aantal stuks
Per stuk
Per pak*
3 - 12
13,397 €
40,191 €
15 - 72
12,28 €
36,84 €
75 - 147
11,67 €
35,01 €
150 - 297
11,27 €
33,81 €
300 +
10,893 €
32,679 €
*prijsindicatie
Related Products
Semiconductor protection fuses, operating class gSWith blade contacts, ...
Description:
Semiconductor protection fuses, operating class gSWith blade contacts, for installation in NH fuse bases or load switchesSITOR NH fuse links are designed for the overload and short circuit protection of cables, wires and power rails as well as for semiconductor ...
Breaking capacity 80kA at 415Vac and 40kA at ...
Description:
Breaking capacity 80kA at 415Vac and 40kA at 250Vdc (bolted connection types) (E1 type 16·5kA at 240Vac)Rated at 415Vac/250Vdc (bolted connection types) (E1 type 240Vac)Electricity Supply Authorities, Lloyd’s Register of Shipping Approvals and ASTA 20 certified.
As the fuse allows for the starting surge ...
Description:
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A. Breaking capacity ...
Industrial type ultra-fast acting URB class DIN80 size ...
Description:
Industrial type ultra-fast acting URB class DIN80 size 00 fuses. Breaking capacity 200kA at 690Vac; 100kA at 600VdcComplies with VDE636-23; IEC269-4Low inductanceVery low I²t (pre-arcing) and I²t (total) valuesLight weight resin bodyVisual fuse status indicatorOverall length 100mm.