Siemens 4 Phase Busbar, 400V ac, 16mm Pitch

  • RS-stocknr. 124-3127
  • Fabrikantnummer 5ST3716
  • Fabrikant Siemens
Datasheets
Wetgeving en conformiteit
N.v.t.
Land van herkomst: CZ
Productomschrijving

Series 5ST3 7 Bus-Bar System

With pin connections
Cut-to-length bar
For 1 or 3-phase line protective switches of the series 5SJ6 and 5SY
No additional connection terminal required for stranded connection up to 35mm²
Excellent accessibility for feeder cable
50→90A load at infeed single-sided/in-centre for 10mm²; 65→120A for 16mm²
Pin type connection
Material: Cu (10mm²); 16mm² fully insulated
Lug spacing: 18mm

Standards

DIN 57606, DIN 57659

Siemens Distribution Boards & Accessories

Type B characteristic offers instantaneous short circuit response level of 3-5 x normal rated current, making it suitable for circuits with moderate inrush currents such as filament lamps, heating loads and most domestic/small building protection applications.,Type C characteristic offers short circuit response of 5-10 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance tripping might occur if a faster type was used.

Specificaties
Kenmerk Waarde
Rated Operational Voltage 400V ac
Material Copper
Range Sentron
Electrical Phase 4
For Use With 4P Miniature Circuit Breakers
Series 5ST
Pitch 16mm
Current Rating 80 A
3 op voorraad - levertijd is 1 werkdag(en)
Prijs Each
146,00
(excl. BTW)
176,66
(incl. BTW)
Aantal stuks
Per stuk
1 +
146,00 €
Related Products
The inner life of the KOPP MCB has ...
Description:
The inner life of the KOPP MCB has changed significantly compared with previous automatic cut-out technology. The thermal actuator consists of a bimetal snap disc that is integrated into the magnetic actuator. This has reduced the number of welded connections ...
Electronic circuit protector type ESX10-T is designed to ...
Description:
Electronic circuit protector type ESX10-T is designed to ensure selective disconnection of DC24V load systems. By active current limitation, ESX10-T responds much faster to overload or short circuit conditions than switch-mode power supply. The ESX10-T limits the highest possible current ...
Range of cutable comb busbars compatible with IC60, ...
Description:
Range of cutable comb busbars compatible with IC60, IID, ISW-NA, IK60, IID K and ISW switch disconnector. Mounting mode: Horizontal Rated operational voltage: 415 V AC Rated insulation voltage: 500 V AC.
The comb busbars make it easier to install ...
Description:
The comb busbars make it easier to install Schneider Electric products. Supplied with 2 side platesSelf-extinguishing insulating material, colour RAL 7016The teeth left on standby can be isolated by tooth cover end-pieces.