Dold 3 Phase Brake Module, 2 kW, 7.5 kW, 400 V ac

  • RS-stocknr. 806-5279
  • Fabrikantnummer BA9034N 25A AC50/60Hz 400V 2-11s
  • Fabrikant Dold
Datasheets
Wetgeving en conformiteit
Conform
Land van herkomst: DE
Productomschrijving

Dold Motor Brake Relay

The BA9034N incorporates automatic standstill monitoring alongside a contactor connected to the DC relay output. Motor restart while DC braking current injection can be avoided thanks to an inter-lock contact & built in safety brake.
Asynchronous motor brake relays are suitable for a variety of both single & three phase motors. A potentiometer allows for adjustment of the braking current scaled from 10-100%, accompanied by an integrated current limit which scales to the current % setting

Features
Suitable for both single & three phase asynchronous motors
Automatic standstill detection
Integrated braking contactor
Easily fitted into existing installations as well as new applications
Microcontroller enabled

Benefits of the BA9034N
Cost effective
No need to monitor current
Compact design
High level of safety & more economic thanks to short stop cycles

DC Brake Modules

A powerbrake unit is used where fast, efficient and predictable stopping of a machine in the shortest possible time is required. Using the d.c. injection method, it provides a controlled deceleration to a stop, by injecting a d.c. current into two of the motor terminals and neutralising the rotating magnetic field in the motor after the 3 phase supply has been disconnected. This stops the motor coasting to a halt and reduces the delay time by this enforced braking. They can be used with a standard 3 phase induction motor. The unit may be located on a piece of machinery or adjacent to it, with little disruption or modification required to the existing wiring. The Powerbrake units provide a simple cost-effective solution to motor braking, which is maintenance and wear-free.,Brake Module - For a brake unit, all the control wiring has to be supplied and installed by the customer, including interlocked contactors and pushbuttons.,Production Brakes - Enclosed brakes with all control wiring included, optional DOL starter built in Injects DC on EVERY stop.,Critical Brake - Enclosed brake with contactors built in. Must be used with existing starter, also AC must pass through the unit so that it can be isolated before DC is injected. Only injects DC when E-stop activated.

Specificaties
Kenmerk Waarde
Phase 3
Starter Included Yes
Power Rating 2 kW, 7.5 kW
Supply Voltage 400 V ac
Enclosure Size 45 x 73 x 122mm
IP Rating IP20, IP40
Enclosure Length 45mm
Enclosure Width 73mm
Enclosure Depth 122mm
Minimum Operating Temperature 0°C
Maximum Operating Temperature +45°C
10 op voorraad - levertijd is 1 werkdag(en)
Prijs Each
249,23
(excl. BTW)
301,57
(incl. BTW)
Aantal stuks
Per stuk
1 +
249,23 €
Related Products
Braking resistors allow Altivar 71 drives to operate ...
Description:
Braking resistors allow Altivar 71 drives to operate while braking to a standstill, by dissipating the braking energy.They enable maximum transient braking torque.Applications are for inertia machines and machines with cycles. Degree of protection is IP20Mounted on the outside of ...
Braking resistors allow Altivar 71 drives to operate ...
Description:
Braking resistors allow Altivar 71 drives to operate while braking to a standstill, by dissipating the braking energy.They enable maximum transient braking torque.Applications are for inertia machines and machines with cycles. Degree of protection is IP20Mounted on the outside of ...
SINAMICS G120 Power Module PM 250 with integrated ...
Description:
SINAMICS G120 Power Module PM 250 with integrated Class A filter capable of energy recovery. 380-480 V 3 AC +10/-10% 47-63 Hz Power high overload: 11kW at 200% 3s, 150% 57s, 100% 240 s, Ambient temperature 0 to +50 °C ...
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN ...
Description:
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 18,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 22KW FOR 150% 3S,110% ...