- RS-stocknr.:
- 836-0739
- Fabrikant:
- RS PRO
3 op voorraad - levertijd is 1 werkdag(en) (EU-voorraad)
26 op voorraad - levertijd is 3 à 5 werkdagen (UK-voorraad)
Toegevoegd
Prijs 1 rol 100 meter
€ 222,86
(excl. BTW)
€ 269,66
(incl. BTW)
Reel(s) | Per reel | Per meter* |
1 - 4 | € 222,86 | € 2,229 |
5 + | € 207,93 | € 2,079 |
*prijsindicatie |
- RS-stocknr.:
- 836-0739
- Fabrikant:
- RS PRO
Wetgeving en conformiteit
- Land van herkomst:
- TR
Productomschrijving
3182B / H05Z1Z1-F LSZH 0.75 Cable
3182B is indoor general wiring cable. These low smoke zero halogen (LSZH) cables can be used in public areas where fire, smoke emission and toxic fumes pose potential threats to life and equipment.
Features and Benefits
Thermoplastic insulation and sheath
LSZH (Low smoke zero halogen)
Flame retardant
Operating temperature range: -5°C to +70°C
Product Application Information
Pendant lighting drops, supply leads in hospitals or airport projects are ideal areas where this type of cable can be used.
Standards
EN 50363-8, EN 50363-7, IEC 60332-1, EN 50525-3-11, Class 5 IEC 60228, RoHS
RS PRO 3 Core 1.5 mm² Power Cable, White 100 m, 500 V, H05Z1Z1-F
This indoor general wiring cable from the RS PRO range is found in public areas where the potential for fire, smoke emissions and toxic fumes would pose a threat to life and equipment. As a low-smoke, zero-halogen cable, it will minimise dangerous emissions in the event of a fire.
The thermoplastic-insulated, flame-retardant cable has an operating temperature range of -5°C to +70°C. It's available in lengths of 100 metres, has an outer diameter of 7.4 to 9.4 mm and a cross-sectional area of 1.5 mm².
This cable has been tested against a range of international standards. It's effective as a Class 5 stranded-copper conducting cable (IEC 60228) and is safely sheathed in a thermoplastic compound (EN 50363-8, EN 50363-7). It also meets fire safety requirements (IEC 60332-1) and contains minimal hazardous substances (RoHS).
Common applications for this cable include pendant lighting drops, supply leads in hospitals and airport projects.
The thermoplastic-insulated, flame-retardant cable has an operating temperature range of -5°C to +70°C. It's available in lengths of 100 metres, has an outer diameter of 7.4 to 9.4 mm and a cross-sectional area of 1.5 mm².
This cable has been tested against a range of international standards. It's effective as a Class 5 stranded-copper conducting cable (IEC 60228) and is safely sheathed in a thermoplastic compound (EN 50363-8, EN 50363-7). It also meets fire safety requirements (IEC 60332-1) and contains minimal hazardous substances (RoHS).
Common applications for this cable include pendant lighting drops, supply leads in hospitals and airport projects.
Features and Benefits
• Low-smoke, zero-halogen cable
• Three-core cable
• 100-metre reel
• Stranded cable with a flame-retardant thermoplastic sheath
• Resistance of 13.3 Ω/km
• Voltage rating of 500 V
• Outer cable diameter of 7.4 to 9.4 mm
• Operating temperature range of -5˚C to +70˚C
• Compliant with IEC 60228, EN 50363-8, EN 50363-7, IEC 60332 and RoHS
• Three-core cable
• 100-metre reel
• Stranded cable with a flame-retardant thermoplastic sheath
• Resistance of 13.3 Ω/km
• Voltage rating of 500 V
• Outer cable diameter of 7.4 to 9.4 mm
• Operating temperature range of -5˚C to +70˚C
• Compliant with IEC 60228, EN 50363-8, EN 50363-7, IEC 60332 and RoHS
RS PRO
RS PRO is our own brand range and brings you a wide range of high-quality, great value products offering you more choice. Trusted by engineers all over the world, every part of every RS PRO product has been rigorously tested against demanding industry standards
theyre only given the RS PRO Seal of Approval if were confident of their exceptional quality, which means you can be confident too.
Specificaties
Kenmerk | Waarde |
---|---|
Cross Sectional Area | 1.5 mm² |
Number of Cores | 3 |
Sheath Colour | White |
Length | 100m |
Cable Type | Fire Performance |
Outer Diameter | 7.4 → 9.4mm |
CPR Certification | Eca |
Voltage Rating | 500 V |
European Harmonised Code | H05Z1Z1-F |
Minimum Operating Temperature | -5°C |
Standards Met | BS EN 50525 |
Conductor Material | Copper |
Size of Strands | 0.25 mm |
Maximum Operating Temperature | +70°C |
Number of Strands | 27 |
American Wire Gauge | 15 AWG |
Conductor Resistance | 13.3 Ω/km |
Fire Behaviour | Flame Retardant |
Insulation Material | Thermoplastic |